{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2026-9717","id":"CVE-2026-9717","title":"CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that co…","description":"CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.","descriptionLong":"CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.","published":"2026-06-25T15:05:36.423Z","updated":"2026-10-25T22:10:00.150Z","reserved":"2026-05-27T16:02:10.875Z","status":"Analyzed","rejected":false,"assigner":"schneider","metric":{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"schneider"},"metrics":[{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"schneider"},{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"se.com"},{"version":"3.1","score":7.2,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"}],"rating":"high","products":["Schneider Electric PowerLogic™ P7"],"affectedProducts":[{"vendor":"Schneider Electric","product":"PowerLogic™ P7","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version V02.003.001.000 and prior"}],"platforms":[]}],"packages":[],"cwes":["CWE-78"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-03.pdf","tags":["Vendor Advisory","Mitigation"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.01727,"epssPercentile":0.78018,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2026-9717","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-9717","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2026-9717","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2026-9717","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}