Out-of-bounds read from received-frame length underflow in the STM32WBA IEEE 802.15.4 driver
zephyrproject zephyr
Affected versions
| Product | Affected | Fixed in |
|---|---|---|
| zephyrproject zephyr |
| No fix yet |
Original description
The STM32WBA IEEE 802.15.4 driver in drivers/ieee802154/ieee802154_stm32wba.c computed the packet length of a received frame as pkt_len = rx_frame->length - IEEE802154_FCS_LENGTH without first checking that the radio-reported length could hold an FCS. pkt_len is a uint8_t, so a reported length of 0 or 1 wrapped to 254 or 255. The only bound on the resulting value was __ASSERT_NO_MSG(pkt_len <= CONFIG_NET_BUF_DATA_SIZE), which compiles to nothing in the default production configuration (CONFIG_ASSERT=n).
The length originates in the ST link-layer receive-done metadata (p_metadata->length, stored by stm32wba_802154_receive_done()), and ultimately in the PHY header of a frame received over the air, so it is influenced by any attacker within radio range of the device. Reaching the underflow requires the vendor link layer to surface a frame shorter than the FCS with no error; the driver performed no validation of its own on that value.