{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2026-4827","id":"CVE-2026-4827","title":"Insufficient Entropy vulnerability on Multiple Products","description":"CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.","descriptionLong":"CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.","published":"2026-05-12T12:24:22.928Z","updated":"2026-10-26T18:10:00.173Z","reserved":"2026-03-25T14:07:29.111Z","status":"Awaiting Analysis","rejected":false,"assigner":"schneider","metric":{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","rating":"high","source":"schneider"},"metrics":[{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","rating":"high","source":"schneider"},{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"se.com"}],"rating":"high","products":["Schneider Electric Easergy MiCOM C264","Schneider Electric Easergy C5","Schneider Electric Easergy MiCOM P30","Schneider Electric Easergy MiCOM P40","Schneider Electric EcoStruxure™ Power Automation System Gateway (EPAS-GTW)","Schneider Electric EcoStruxure™ Power Automation System User Interface (EPAS-UI)","Schneider Electric EcoStruxure™ Power Operation","Schneider Electric iPMFLS","Schneider Electric PowerLogic™ P5 Protection Relay","Schneider Electric PowerLogic™ P7 Protection and Control Platform","Schneider Electric PowerLogic™ T300","Schneider Electric PowerLogic™ T500","Schneider Electric Saitel DP","Schneider Electric EasyLogic T150 (formerly Saitel DR)"],"affectedProducts":[{"vendor":"Schneider Electric","product":"Easergy MiCOM C264","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions D6.x"},{"status":"affected","version":"Versions D7.33 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Easergy C5","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 1.1.17 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Easergy MiCOM P30","defaultStatus":"unaffected","versions":[{"status":"affected","version":"P139 version prior to P139.678.700"},{"status":"affected","version":"P437 version prior to P437.678.700"},{"status":"affected","version":"P439 version prior to P439.678.700"},{"status":"affected","version":"P532 version prior to P532.678.700"},{"status":"affected","version":"P539 version prior to P539.678.700"},{"status":"affected","version":"P631 version prior to P631.678.700"},{"status":"affected","version":"P632 version prior to P632.678.700"},{"status":"affected","version":"P633 version prior to P633.678.700"},{"status":"affected","version":"P634 version prior to P634.678.700"},{"status":"affected","version":"P633 version P633.680.700 only"},{"status":"affected","version":"P634 version P634.680.700 only"},{"status":"affected","version":"P138 version prior to P138.677.700"},{"status":"affected","version":"P436 version prior to P436.677.701"},{"status":"affected","version":"P438 version prior to P438.677.701"},{"status":"affected","version":"P638 version prior to P638.677.700"},{"status":"affected","version":"C434 version prior to C434.679.700"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Easergy MiCOM P40","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Series model numbers with Protocol Option bit as G, H or L and all firmware versions"}],"platforms":[]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Automation System Gateway (EPAS-GTW)","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 6.4.616.200.100 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Automation System User Interface (EPAS-UI)","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 3.0.3 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Operation","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 2022 CU6 and prior"},{"status":"affected","version":"Version 2024 CU2 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"iPMFLS","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 64.2025.0.13 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"PowerLogic™ P5 Protection Relay","defaultStatus":"unaffected","versions":[{"status":"affected","version":"V02.502.103 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"PowerLogic™ P7 Protection and Control Platform","defaultStatus":"unaffected","versions":[{"status":"affected","version":"V02.002.002 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"PowerLogic™ T300","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 2.9.4 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"PowerLogic™ T500","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 11.08.02 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Saitel DP","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 11.06.36 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"EasyLogic T150 (formerly Saitel DR)","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 11.06.30 and prior"}],"platforms":[]}],"packages":[],"cwes":["CWE-331"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-02.pdf","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total"},"epss":0.00312,"epssPercentile":0.24425,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2026-4827","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-4827","ok":true,"note":"Awaiting Analysis"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2026-4827","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2026-4827","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}