atm: fore200e: fix use-after-free in tasklets during device removal
Linux
Affected versions
| Product | Affected | Fixed in |
|---|---|---|
| Linux Linux |
|
Linux
| Product | Affected | Fixed in |
|---|---|---|
| Linux Linux |
|
≥ 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2 · < e4ff4e3ffcf9d5aad380cdd1d8cdc008bb34f97d| No fix yet |
| Linux Linux |
|
|
In the Linux kernel, the following vulnerability has been resolved:
atm: fore200e: fix use-after-free in tasklets during device removal
When the PCA-200E or SBA-200E adapter is being detached, the fore200e is deallocated. However, the tx_tasklet or rx_tasklet may still be running or pending, leading to use-after-free bug when the already freed fore200e is accessed again in fore200e_tx_tasklet() or fore200e_rx_tasklet().
One of the race conditions can occur as follows:
CPU 0 (cleanup) | CPU 1 (tasklet) fore200e_pca_remove_one() | fore200e_interrupt() fore200e_shutdown() | tasklet_schedule() kfree(fore200e) | fore200e_tx_tasklet() | fore200e-> // UAF
Fix this by ensuring tx_tasklet or rx_tasklet is properly canceled before the fore200e is released. Add tasklet_kill() in fore200e_shutdown() to synchronize with any pending or running tasklets. Moreover, since fore200e_reset() could prevent further interrupts or data transfers, the tasklet_kill() should be placed after fore200e_reset() to prevent the tasklet from being rescheduled in fore200e_interrupt(). Finally, it only needs to do tasklet_kill() when the fore200e state is greater than or equal to FORE200E_STATE_IRQ, since tasklets are uninitialized in earlier states. In a word, the tasklet_kill() should be placed in the FORE200E_STATE_IRQ branch within the switch...case structure.
This bug was identified through static analysis.
From the CVE record · Linux
The Linux kernel’s fore200e ATM driver can access freed memory if a transmit or receive tasklet is still running or pending when a PCA-200E or SBA-200E adapter is removed. This race can cause a use-after-free; the input does not establish an attacker path, authentication requirement, or user-interaction requirement.
Engineers running Linux kernels with the fore200e driver and PCA-200E or SBA-200E adapters should check their kernel versions; affected versions were not provided.