{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2026-33135","id":"CVE-2026-33135","title":"WeGIA has Reflected Cross-Site Scripting (XSS) in `novo_memorandoo.php` via `sccs` parameter","description":"WeGIA is a web manager for charitable institutions. Versions 3.6.6 and below have a Reflected Cross-Site Scripting (XSS) vulnerability in the novo_memorandoo.php endpoint. An attacker can inject arbitrary JavaScript into the sccs GET parameter, which is directly echoed into the HTML response without any sanitization or encoding. The script /html/memorando/novo_memorandoo.php reads HTTP GET paramet","descriptionLong":"WeGIA is a web manager for charitable institutions. Versions 3.6.6 and below have a Reflected Cross-Site Scripting (XSS) vulnerability in the novo_memorandoo.php endpoint. An attacker can inject arbitrary JavaScript into the sccs GET parameter, which is directly echoed into the HTML response without any sanitization or encoding. The script /html/memorando/novo_memorandoo.php reads HTTP GET parameters to display dynamic success messages to the user. At approximately line 273, the code checks if $_GET['msg'] equals 'success'. If true, it directly concatenates $_GET['sccs'] into an HTML alert <div> and outputs it to the browser. This issue has been fixed in version 3.6.7.","published":"2026-03-20T10:38:44.065Z","updated":"2026-10-28T02:31:13.652318274Z","reserved":"2026-03-17T20:35:49.928Z","status":"Analyzed","rejected":false,"assigner":"GitHub_M","metric":{"version":"3.1","score":9.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N","rating":"critical","source":"GitHub_M"},"metrics":[{"version":"3.1","score":9.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N","rating":"critical","source":"GitHub_M"},{"version":"3.1","score":9.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N","rating":"critical","source":"github.com"},{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","rating":"medium","source":"NVD"},{"version":"3.1","score":9.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N","rating":"critical","source":"OSV"}],"rating":"critical","products":["LabRedesCefetRJ WeGIA"],"affectedProducts":[{"vendor":"LabRedesCefetRJ","product":"WeGIA","defaultStatus":null,"versions":[{"version":"< 3.6.7","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-79"],"aliases":["GHSA-w5rv-5884-w94v"],"references":[{"url":"https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-w5rv-5884-w94v","tags":["x_refsource_CONFIRM","exploit","Exploit","Vendor Advisory","advisory"]},{"url":"https://github.com/LabRedesCefetRJ/WeGIA/pull/1459","tags":["x_refsource_MISC","Issue Tracking","Patch","fix"]},{"url":"https://github.com/LabRedesCefetRJ/WeGIA/releases/tag/3.6.7","tags":["x_refsource_MISC","Release Notes","web"]},{"url":"https://github.com/CVEProject/cvelistV5/tree/main/cves/2026/33xxx/CVE-2026-33135.json","tags":["advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-33135","tags":["advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":true,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"total"},"epss":0.00262,"epssPercentile":0.18194,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2026-33135","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-33135","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2026-33135","ok":true,"note":"0 packages"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2026-33135","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}