{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2026-27512","id":"CVE-2026-27512","title":"Tenda F3 Reflected Script Execution via Missing nosniff Header","description":"Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a content-type confusion vulnerability in the administrative interface. Responses omit the X-Content-Type-Options: nosniff header and include attacker-influenced content that can be reflected into the response body. Under affected browser behaviors, MIME sniffing may cause the response to be interpreted as active HTML, enabling","descriptionLong":"Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a content-type confusion vulnerability in the administrative interface. Responses omit the X-Content-Type-Options: nosniff header and include attacker-influenced content that can be reflected into the response body. Under affected browser behaviors, MIME sniffing may cause the response to be interpreted as active HTML, enabling script execution in the context of the administrative interface.","published":"2026-02-23T16:26:20.398Z","updated":"2026-06-17T10:27:16.993Z","reserved":"2026-02-19T19:51:07.328Z","status":"Analyzed","rejected":false,"assigner":"VulnCheck","metric":{"version":"4.0","score":5.1,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N","rating":"medium","source":"VulnCheck"},"metrics":[{"version":"4.0","score":5.1,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N","rating":"medium","source":"VulnCheck"},{"version":"4.0","score":5.1,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"medium","source":"vulncheck.com"},{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","rating":"medium","source":"VulnCheck"},{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","rating":"medium","source":"vulncheck.com"}],"rating":"medium","products":["Shenzhen Tenda Technology Co., Ltd. Tenda F3"],"affectedProducts":[{"vendor":"Shenzhen Tenda Technology Co., Ltd.","product":"Tenda F3","defaultStatus":"unknown","versions":[{"lessThanOrEqual":"12.01.01.55_multi","status":"affected","version":"0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-79","CWE-116"],"aliases":[],"references":[{"url":"https://www.tendacn.com/product/F3","tags":["product","Product"]},{"url":"https://www.vulncheck.com/advisories/tenda-f3-reflected-script-execution-via-missing-nosniff-header","tags":["third-party-advisory","Third Party Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00223,"epssPercentile":0.13129,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2026-27512","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-27512","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2026-27512","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2026-27512","ok":true,"note":"scored 2026-11-20"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}