{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2026-22755","id":"CVE-2026-22755","title":"Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi","description":"Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, M","descriptionLong":"Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.","published":"2026-01-13T15:12:53.126Z","updated":"2026-06-17T10:20:22.553Z","reserved":"2026-01-09T14:27:11.646Z","status":"Deferred","rejected":false,"assigner":"larry_cashdollar","metric":{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Amber","rating":"critical","source":"larry_cashdollar"},"metrics":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Amber","rating":"critical","source":"larry_cashdollar"},{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:X/U:Amber","rating":"critical","source":"me.com"}],"rating":"critical","products":["Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330"],"affectedProducts":[{"vendor":"Vivotek","product":"Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330","defaultStatus":"unaffected","versions":[{"status":"affected","version":"0100a","versionType":"custom"},{"status":"affected","version":"0106a","versionType":"custom"},{"status":"affected","version":"0106b","versionType":"custom"},{"status":"affected","version":"0107a","versionType":"custom"},{"status":"affected","version":"0107b_1","versionType":"custom"},{"status":"affected","version":"0109a","versionType":"custom"},{"status":"affected","version":"0112a","versionType":"custom"},{"status":"affected","version":"0113a","versionType":"custom"},{"status":"affected","version":"0113d","versionType":"custom"},{"status":"affected","version":"0117b","versionType":"custom"},{"status":"affected","version":"0119e","versionType":"custom"},{"status":"affected","version":"0120b","versionType":"custom"},{"status":"affected","version":"0121","versionType":"custom"},{"status":"affected","version":"0121d","versionType":"custom"},{"status":"affected","version":"0121d_48573_1","versionType":"custom"},{"status":"affected","version":"0122e","versionType":"custom"},{"status":"affected","version":"0124d_48573_1","versionType":"custom"},{"status":"affected","version":"012501","versionType":"custom"},{"status":"affected","version":"012502","versionType":"custom"},{"status":"affected","version":"0125c","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-77"],"aliases":[],"references":[{"url":"http://www.vapidlabs.com/advisory.php?v=220","tags":[]},{"url":"https://www.akamai.com/blog/security-research/command-injection-vivotek-legacy-firmware-need-to-know","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"poc","automatable":"yes","technicalImpact":"total"},"epss":0.13806,"epssPercentile":0.96592,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2026-22755","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-22755","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2026-22755","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2026-22755","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":["EPSS 14% with CVSS 9.3"],"attention":null}