{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2026-2273","id":"CVE-2026-2273","title":"CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of u…","description":"CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.","descriptionLong":"CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.","published":"2026-03-10T17:18:39.374Z","updated":"2026-06-23T13:53:23.937Z","reserved":"2026-02-10T09:45:08.807Z","status":"Analyzed","rejected":false,"assigner":"schneider","metric":{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:L/VI:H/VA:L/SC:H/SI:H/SA:H","rating":"high","source":"schneider"},"metrics":[{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:L/VI:H/VA:L/SC:H/SI:H/SA:H","rating":"high","source":"schneider"},{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:L/VI:H/VA:L/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"se.com"},{"version":"3.1","score":8.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"NVD"}],"rating":"high","products":["Schneider Electric EcoStruxure™ Automation Expert"],"affectedProducts":[{"vendor":"Schneider Electric","product":"EcoStruxure™ Automation Expert","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions prior to v25.0.1"}],"platforms":[]}],"packages":[],"cwes":["CWE-94"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-04.pdf","tags":["Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00272,"epssPercentile":0.1988,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2026-2273","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-2273","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2026-2273","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2026-2273","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}