Insecure Session ID Management Vulnerability in Tenda Wireless Routers
Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router
Affected versions
| Product | Affected | Fixed in |
|---|---|---|
| Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router |
| No fix yet |
Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router
| Product | Affected | Fixed in |
|---|---|---|
| Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router |
| No fix yet |
This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission. Successful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device.
From the CVE record · CERT-In
The Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router use login credentials as a session ID in their web-based administrative interface. A remote attacker who intercepts the session ID during insecure network transmission could hijack an authenticated session and access sensitive device configuration information.
Anyone running a Tenda 300Mbps Wireless Router F3 or N300 Easy Setup Router should check; affected versions were not specified.