{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2026-129713","id":"CVE-2026-129713","title":"Danfoss AK-SM8xxA denial of service in unauthenticated CGI handler","description":"A stack-based buffer overflow in an unauthenticated CGI handler of the\nDanfoss AK-SM 8xxA Series controller allows remote attackers to send specially\ncrafted HTTP/S POST requests, leading to memory corruption, webserver restart\nand hypothetically potential arbitrary code execution with webserver privileges.\nAuthentication is not required to exploit this vulnerability.","descriptionLong":"A stack-based buffer overflow in an unauthenticated CGI handler of the\nDanfoss AK-SM 8xxA Series controller allows remote attackers to send specially\ncrafted HTTP/S POST requests, leading to memory corruption, webserver restart\nand hypothetically potential arbitrary code execution with webserver privileges.\nAuthentication is not required to exploit this vulnerability.","published":"2026-11-20T10:49:40.291Z","updated":"2026-11-20T11:18:30.953Z","reserved":"2026-11-16T09:00:14.479Z","status":"Received","rejected":false,"assigner":"Danfoss","metric":{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"critical","source":"Danfoss"},"metrics":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"critical","source":"Danfoss"},{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"critical","source":"d7ff35af-cf88-454c-bab9-af60602f10f8"}],"rating":"critical","products":["Danfoss AK-SM8xxA"],"affectedProducts":[{"vendor":"Danfoss","product":"AK-SM8xxA","defaultStatus":"unaffected","versions":[{"status":"affected","version":"0","lessThanOrEqual":"5.4.0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-121"],"aliases":[],"references":[{"url":"https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2026-12-01/","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":null,"epssPercentile":null,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2026-129713","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-129713","ok":true,"note":"Received"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2026-129713","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2026-129713","ok":false,"note":"no score yet"}],"aiTitle":true,"tech":[],"critical":[],"attention":null}