DJI AeroScope Mobile root login via board serial console
DJI AeroScope Mobile (TP703) · DJI AeroScope Mobile (TP703) 1300 communications board firmware
Affected versions
| Product | Affected | Fixed in |
|---|---|---|
| DJI AeroScope Mobile (TP703) ARM |
| No fix yet |
| DJI AeroScope Mobile (TP703) 1300 communications board firmware ARM |
| No fix yet |
Original description
Use of hard-coded credentials (CWE-798) on the 1300 communications board in DJI AeroScope Mobile (TP703) firmware 03.00.00.26, with 1300 communications board firmware 02.00.07.12 through 02.00.08.40, allows an attacker with physical access to the board's serial console to log in as root. The same password hash is present on every unit and uses DES crypt, so the password can be recovered offline from the distributed firmware. No network login service accepts this password by default. Confirmed on a physical device.