{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2026-12486","id":"CVE-2026-12486","title":"GeoVision GV-I/O Box 4E libNetSetObj.so OS command injection vulnerability","description":"Multiple OS command injection vulnerabilities exist in the libNetSetObj.so functionality of GeoVision GV-I/O Box 4E 2.09. A specially crafted network packet can lead to command execution. An attacker can send a network request to trigger this vulnerability.\n\n\n`libNetSetObj.so` is an internal library used by various binaries on the device to configure the network stack (start and stop various servi","descriptionLong":"Multiple OS command injection vulnerabilities exist in the libNetSetObj.so functionality of GeoVision GV-I/O Box 4E 2.09. A specially crafted network packet can lead to command execution. An attacker can send a network request to trigger this vulnerability.\n\n\n`libNetSetObj.so` is an internal library used by various binaries on the device to configure the network stack (start and stop various services, configure IP, Netmask, gateway, dns, etc.)\n\n\n#### CNetSetObj::m_F_n_Set_IP_Addr command injection\n\nThe following function takes a string as an ip address, performs no sanitization and calls `system`. This is a classic command injection vulnerability. The function is reachable from both the network-exposed `DVRSearch` service and the `Network.cgi` endpoint. \n\n\n\n    int __fastcall CNetSetObj::m_F_n_Set_IP_Addr(const char **this, char *ip_addr)\n\n    {\n\n      bool v2; // zf\n\n      char v4[72]; // [sp+0h] [bp-48h] BYREF\n\n\n\n      v2 = *this == 0;\n\n      if ( *this )\n\n        v2 = ip_addr == 0;\n\n      if ( v2 )\n\n        return 0;\n\n      sprintf(v4, \"/sbin/ifconfig %s %s\", *this, ip_addr);  // attacker controlled ip address \n\n      system(v4);\n\n      return 1;\n\n    }","published":"2026-06-24T03:40:19.795Z","updated":"2026-10-25T23:10:00.167Z","reserved":"2026-06-17T03:09:07.610Z","status":"Deferred","rejected":false,"assigner":"GV","metric":{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"GV"},"metrics":[{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"GV"},{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"0df08a0e-a200-4957-9bb0-084f562506f9"}],"rating":"critical","products":["GeoVision Inc. GV-I/O Box 4E"],"affectedProducts":[{"vendor":"GeoVision Inc.","product":"GV-I/O Box 4E","defaultStatus":"unaffected","versions":[{"status":"affected","version":"V2.09"},{"status":"unaffected","version":"V2.12"}],"platforms":["Linux"]}],"packages":[],"cwes":["CWE-78"],"aliases":[],"references":[{"url":"https://www.geovision.com.tw/cyber_security.php","tags":["vendor-advisory"]},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2026-2379","tags":["third-party-advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.02703,"epssPercentile":0.86236,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2026-12486","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-12486","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2026-12486","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2026-12486","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}