{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2026-118462","id":"CVE-2026-118462","title":"CGM Infantia, Profim and Venere code execution in update components","description":"Update components download and execute code without proper authenticity verification, relying on ignored hashes or forgeable checksums. Some update paths also permit archive traversal or script execution.","descriptionLong":"Update components download and execute code without proper authenticity verification, relying on ignored hashes or forgeable checksums. Some update paths also permit archive traversal or script execution.","published":"2026-11-09T11:51:58.643Z","updated":"2026-11-12T20:18:18.117Z","reserved":"2026-10-28T08:46:25.411Z","status":"Deferred","rejected":false,"assigner":"ENISA","metric":{"version":"4.0","score":9.2,"vector":"CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"critical","source":"ENISA"},"metrics":[{"version":"4.0","score":9.2,"vector":"CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"critical","source":"ENISA"},{"version":"4.0","score":9.2,"vector":"CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"critical","source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"}],"rating":"critical","products":["CompuGroup Medical Infantia","CompuGroup Medical Profim","CompuGroup Medical Venere","CompuGroup Medical Phronesis"],"affectedProducts":[{"vendor":"CompuGroup Medical","product":"Infantia","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThanOrEqual":"1.3.0","versionType":"semver"}],"platforms":[]},{"vendor":"CompuGroup Medical","product":"Profim","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThanOrEqual":"1.3.0","versionType":"semver"}],"platforms":[]},{"vendor":"CompuGroup Medical","product":"Venere","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThanOrEqual":"1.3.0","versionType":"semver"}],"platforms":[]},{"vendor":"CompuGroup Medical","product":"Phronesis","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThanOrEqual":"1.3.0","versionType":"semver"}],"platforms":[]},{"vendor":"CompuGroup Medical","product":"Infantia","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThanOrEqual":"2.12.0","versionType":"semver"}],"platforms":[]},{"vendor":"CompuGroup Medical","product":"Profim","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThanOrEqual":"2.12.0","versionType":"semver"}],"platforms":[]},{"vendor":"CompuGroup Medical","product":"Venere","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThanOrEqual":"2.12.0","versionType":"semver"}],"platforms":[]},{"vendor":"CompuGroup Medical","product":"Phronesis","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThanOrEqual":"2.12.0","versionType":"semver"}],"platforms":[]}],"packages":[],"cwes":["CWE-494"],"aliases":[],"references":[{"url":"https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical","tags":[]},{"url":"https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00167,"epssPercentile":0.06098,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2026-118462","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-118462","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2026-118462","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2026-118462","ok":true,"note":"scored 2026-11-19"}],"aiTitle":true,"tech":[],"critical":[],"attention":null}