{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2026-0667","id":"CVE-2026-0667","title":"CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution…","description":"CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when communicating over the Modbus TCP protocol.","descriptionLong":"CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when communicating over the Modbus TCP protocol.","published":"2026-07-29T12:35:34.208Z","updated":"2026-07-30T16:43:03.817Z","reserved":"2026-01-07T15:42:11.892Z","status":"Awaiting Analysis","rejected":false,"assigner":"schneider","metric":{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"critical","source":"schneider"},"metrics":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"critical","source":"schneider"},{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"critical","source":"se.com"}],"rating":"critical","products":["Schneider Electric SCADAPack 47x","Schneider Electric SCADAPack 47xi","Schneider Electric SCADAPack 57x","Schneider Electric RemoteConnect"],"affectedProducts":[{"vendor":"Schneider Electric","product":"SCADAPack 47x","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions prior to R3.4.2 (Firmware version prior to 9.12.2)"}],"platforms":[]},{"vendor":"Schneider Electric","product":"SCADAPack 47xi","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions prior to R3.4.2 (Firmware version prior to 9.12.2)"}],"platforms":[]},{"vendor":"Schneider Electric","product":"SCADAPack 57x","defaultStatus":"unaffected","versions":[{"status":"affected","version":"All Versions"}],"platforms":[]},{"vendor":"Schneider Electric","product":"RemoteConnect","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions prior to R3.4.2"}],"platforms":[]}],"packages":[],"cwes":["CWE-754"],"aliases":[],"references":[{"url":"https://download.se.com/files?p_Doc_Ref=SEVD-2026-041-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-041-01.pdf","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total"},"epss":0.00531,"epssPercentile":0.45616,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2026-0667","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-0667","ok":true,"note":"Awaiting Analysis"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2026-0667","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2026-0667","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}