{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-8449","id":"CVE-2025-8449","title":"CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenti…","description":"CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network.","descriptionLong":"CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network.","published":"2025-08-20T13:55:34.397Z","updated":"2026-06-17T10:07:00.603Z","reserved":"2025-07-31T21:02:44.262Z","status":"Deferred","rejected":false,"assigner":"schneider","metric":{"version":"4.0","score":4.1,"vector":"CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","rating":"medium","source":"schneider"},"metrics":[{"version":"4.0","score":4.1,"vector":"CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","rating":"medium","source":"schneider"},{"version":"4.0","score":4.1,"vector":"CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"medium","source":"se.com"}],"rating":"medium","products":["Schnieder Electric EcoStruxure Building Operation Enterprise Server","Schneider Electric EcoStruxure Enterprise Server","Schneider Eelctric EcoStruxure Building Operation Workstation"],"affectedProducts":[{"vendor":"Schnieder Electric","product":"EcoStruxure Building Operation Enterprise Server","defaultStatus":"unaffected","versions":[{"lessThan":"7.0.2.348","status":"affected","version":"All 7.x versions","versionType":"version"},{"lessThan":"6.0.4.10001 (CP8)","status":"unaffected","version":"All 6.x versions","versionType":"version"},{"lessThan":"5.0.3.17009 (CP16)","status":"affected","version":"All 5.x versions","versionType":"version"}],"platforms":[]},{"vendor":"Schneider Electric","product":"EcoStruxure Enterprise Server","defaultStatus":"unaffected","versions":[{"lessThan":"7.0.2.348","status":"unaffected","version":"All 7.x versions","versionType":"version"},{"lessThan":"6.0.4.10001 (CP8)","status":"affected","version":"All 6.x versions","versionType":"version"},{"lessThan":"5.0.3.17009 (CP16)","status":"affected","version":"All 5.x versions","versionType":"version"}],"platforms":[]},{"vendor":"Schneider Eelctric","product":"EcoStruxure Building Operation Workstation","defaultStatus":"unaffected","versions":[{"lessThan":"7.0.2.348","status":"affected","version":"All 7.x versions","versionType":"version"},{"lessThan":"6.0.4.10001 (CP8)","status":"affected","version":"All 6.x versions","versionType":"version"},{"lessThan":"5.0.3.17009 (CP16)","status":"affected","version":"All 5.x versions","versionType":"version"}],"platforms":[]}],"packages":[],"cwes":["CWE-400"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-224-04.pdf","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00283,"epssPercentile":0.21219,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-8449","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-8449","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-8449","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-8449","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}