{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-62597","id":"CVE-2025-62597","title":"WeGIA Vulnerable to Reflected Cross-Site Scripting via Endpoint 'pessoa/editar_info_pessoal.php' Parameter 'sql'","description":"WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. Prior to version 3.5.1, a reflected cross-site scripting (XSS) vulnerability was identified in the editar_info_pessoal.php endpoint of the WeGIA application. This vulnerability allows attackers to inject malicious scripts in the sql parameter. The vulnerable endpoint is GET /WeGIA/html/pessoa/editar_inf","descriptionLong":"WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. Prior to version 3.5.1, a reflected cross-site scripting (XSS) vulnerability was identified in the editar_info_pessoal.php endpoint of the WeGIA application. This vulnerability allows attackers to inject malicious scripts in the sql parameter. The vulnerable endpoint is GET /WeGIA/html/pessoa/editar_info_pessoal.php?sql=1. This issue has been patched in version 3.5.1.","published":"2025-10-21T16:34:19.775Z","updated":"2026-10-28T02:30:50.153622525Z","reserved":"2025-10-16T19:24:37.267Z","status":"Analyzed","rejected":false,"assigner":"GitHub_M","metric":{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:N","rating":"medium","source":"GitHub_M"},"metrics":[{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:N","rating":"medium","source":"GitHub_M"},{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"medium","source":"github.com"},{"version":"4.0","score":null,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:N","rating":"unrated","source":"OSV"},{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","rating":"medium","source":"NVD"}],"rating":"medium","products":["LabRedesCefetRJ WeGIA"],"affectedProducts":[{"vendor":"LabRedesCefetRJ","product":"WeGIA","defaultStatus":null,"versions":[{"version":"< 3.5.1","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-79"],"aliases":["GHSA-wqjv-fhc9-h7hm"],"references":[{"url":"https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-wqjv-fhc9-h7hm","tags":["x_refsource_CONFIRM","Exploit","Vendor Advisory","advisory"]},{"url":"https://github.com/LabRedesCefetRJ/WeGIA/commit/e41395fe6a7b4f428b1797a8d5b52e0e3dbbb3d9","tags":["x_refsource_MISC","Patch","fix"]},{"url":"https://github.com/LabRedesCefetRJ/WeGIA/releases/tag/3.5.1","tags":["x_refsource_MISC","Release Notes","web"]},{"url":"https://github.com/CVEProject/cvelistV5/tree/main/cves/2025/62xxx/CVE-2025-62597.json","tags":["advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-62597","tags":["advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":true,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"poc","automatable":"yes","technicalImpact":"partial"},"epss":0.00294,"epssPercentile":0.22358,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-62597","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-62597","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-62597","ok":true,"note":"0 packages"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-62597","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}