{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-5444","id":"CVE-2025-5444","title":"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection","description":"A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The att","descriptionLong":"A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","published":"2025-06-02T12:00:17.752Z","updated":"2026-06-17T09:47:56.480Z","reserved":"2025-06-01T17:06:30.726Z","status":"Analyzed","rejected":false,"assigner":"VulDB","metric":{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N","rating":"medium","source":"VulDB"},"metrics":[{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N","rating":"medium","source":"VulDB"},{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"medium","source":"vuldb.com"},{"version":"3.1","score":6.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","rating":"medium","source":"VulDB"},{"version":"3.1","score":6.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","rating":"medium","source":"vuldb.com"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"NVD"},{"version":"3.0","score":6.3,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","rating":"medium","source":"VulDB"},{"version":"2.0","score":6.5,"vector":"AV:N/AC:L/Au:S/C:P/I:P/A:P","rating":"medium","source":"VulDB"},{"version":"2.0","score":6.5,"vector":"AV:N/AC:L/Au:S/C:P/I:P/A:P","rating":"medium","source":"vuldb.com"}],"rating":"medium","products":["Linksys RE6500","Linksys RE6250","Linksys RE6300","Linksys RE6350","Linksys RE7000","Linksys RE9000"],"affectedProducts":[{"vendor":"Linksys","product":"RE6500","defaultStatus":null,"versions":[{"version":"1.0.013.001","status":"affected"},{"version":"1.0.04.001","status":"affected"},{"version":"1.0.04.002","status":"affected"},{"version":"1.1.05.003","status":"affected"},{"version":"1.2.07.001","status":"affected"}],"platforms":[]},{"vendor":"Linksys","product":"RE6250","defaultStatus":null,"versions":[{"version":"1.0.013.001","status":"affected"},{"version":"1.0.04.001","status":"affected"},{"version":"1.0.04.002","status":"affected"},{"version":"1.1.05.003","status":"affected"},{"version":"1.2.07.001","status":"affected"}],"platforms":[]},{"vendor":"Linksys","product":"RE6300","defaultStatus":null,"versions":[{"version":"1.0.013.001","status":"affected"},{"version":"1.0.04.001","status":"affected"},{"version":"1.0.04.002","status":"affected"},{"version":"1.1.05.003","status":"affected"},{"version":"1.2.07.001","status":"affected"}],"platforms":[]},{"vendor":"Linksys","product":"RE6350","defaultStatus":null,"versions":[{"version":"1.0.013.001","status":"affected"},{"version":"1.0.04.001","status":"affected"},{"version":"1.0.04.002","status":"affected"},{"version":"1.1.05.003","status":"affected"},{"version":"1.2.07.001","status":"affected"}],"platforms":[]},{"vendor":"Linksys","product":"RE7000","defaultStatus":null,"versions":[{"version":"1.0.013.001","status":"affected"},{"version":"1.0.04.001","status":"affected"},{"version":"1.0.04.002","status":"affected"},{"version":"1.1.05.003","status":"affected"},{"version":"1.2.07.001","status":"affected"}],"platforms":[]},{"vendor":"Linksys","product":"RE9000","defaultStatus":null,"versions":[{"version":"1.0.013.001","status":"affected"},{"version":"1.0.04.001","status":"affected"},{"version":"1.0.04.002","status":"affected"},{"version":"1.1.05.003","status":"affected"},{"version":"1.2.07.001","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-78","CWE-77"],"aliases":[],"references":[{"url":"https://vuldb.com/?id.310783","tags":["vdb-entry","technical-description","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?ctiid.310783","tags":["signature","permissions-required","Permissions Required"]},{"url":"https://vuldb.com/?submit.584366","tags":["third-party-advisory","Third Party Advisory","VDB Entry"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_7/7.md","tags":["exploit","Exploit","Third Party Advisory"]},{"url":"https://www.linksys.com/","tags":["product","Product"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":true,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial"},"epss":0.1356,"epssPercentile":0.96534,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-5444","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-5444","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-5444","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-5444","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}