{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-52952","id":"CVE-2025-52952","title":"Junos OS: MX Series with MPC-BUILTIN, MPC 1 through MPC 9: Receipt and processing of a malformed packet causes one or more FPCs to crash","description":"An Out-of-bounds Write vulnerability in the connectivity fault management (CFM) daemon of Juniper Networks Junos OS on MX Series with MPC-BUILTIN, MPC1 through MPC9 line cards allows an unauthenticated adjacent attacker to send a malformed packet to the device, leading to an FPC crash and restart, resulting in a Denial of Service (DoS).\n\nContinued receipt and processing of this packet will create ","descriptionLong":"An Out-of-bounds Write vulnerability in the connectivity fault management (CFM) daemon of Juniper Networks Junos OS on MX Series with MPC-BUILTIN, MPC1 through MPC9 line cards allows an unauthenticated adjacent attacker to send a malformed packet to the device, leading to an FPC crash and restart, resulting in a Denial of Service (DoS).\n\nContinued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition.\n\nThis issue affects Juniper Networks:\nJunos OS:\n  *  All versions before 22.2R3-S1,\n  *  from 22.4 before 22.4R2.\n\n\nThis feature is not enabled by default.","published":"2025-07-11T15:04:35.691Z","updated":"2026-06-17T09:37:19.537Z","reserved":"2025-06-23T13:16:01.409Z","status":"Analyzed","rejected":false,"assigner":"juniper","metric":{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:A/V:C/RE:M/U:Green","rating":"high","source":"juniper"},"metrics":[{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:A/V:C/RE:M/U:Green","rating":"high","source":"juniper"},{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:A/V:C/RE:M/U:Green","rating":"high","source":"juniper.net"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"juniper"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"juniper.net"}],"rating":"high","products":["Juniper Networks Junos OS"],"affectedProducts":[{"vendor":"Juniper Networks","product":"Junos OS","defaultStatus":"unaffected","versions":[{"lessThan":"22.2R3-S1","status":"affected","version":"0","versionType":"semver"},{"lessThan":"22.4R2","status":"affected","version":"22.4","versionType":"semver"}],"platforms":["MX Series with MPC-BUILTIN","MPC1 through MPC9"]}],"packages":[],"cwes":["CWE-787"],"aliases":[],"references":[{"url":"https://supportportal.juniper.net/JSA100058","tags":["vendor-advisory","Vendor Advisory"]},{"url":"https://www.juniper.net/documentation/us/en/software/junos/network-mgmt/topics/topic-map/cfm-configuring.html","tags":["technical-description","Product"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.0031,"epssPercentile":0,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-52952","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-52952","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-52952","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-52952","ok":true,"note":"scored "}],"aiTitle":false,"tech":["juniper"],"critical":[],"attention":null}