{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-4647","id":"CVE-2025-4647","title":"A user with elevated privileges can bypass sanitization measures by replacing the content of an existing SVG","description":"Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon web allows Reflected XSS.\n\nA user with elevated privileges can bypass sanitization measures by replacing the content of an existing SVG.\n\nThis issue affects web: from 24.10.0 before 24.10.5, from 24.04.0 before 24.04.11, from 23.10.0 before 23.10.22, from 23.04.0 before 23.04.27, f","descriptionLong":"Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon web allows Reflected XSS.\n\nA user with elevated privileges can bypass sanitization measures by replacing the content of an existing SVG.\n\nThis issue affects web: from 24.10.0 before 24.10.5, from 24.04.0 before 24.04.11, from 23.10.0 before 23.10.22, from 23.04.0 before 23.04.27, from 22.10.0 before 22.10.29.","published":"2025-05-13T09:31:17.529Z","updated":"2026-10-28T02:31:15.001672777Z","reserved":"2025-05-13T09:25:32.395Z","status":"Analyzed","rejected":false,"assigner":"Centreon","metric":{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"Centreon"},"metrics":[{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"Centreon"},{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"bd4443e6-1eef-43f3-9886-25fc9ceeaae7"},{"version":"3.1","score":4.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N","rating":"medium","source":"NVD"},{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"OSV"}],"rating":"high","products":["Centreon web"],"affectedProducts":[{"vendor":"Centreon","product":"web","defaultStatus":"unaffected","versions":[{"lessThan":"24.10.5","status":"affected","version":"24.10.0","versionType":"semver"},{"lessThan":"24.04.11","status":"affected","version":"24.04.0","versionType":"semver"},{"lessThan":"23.10.22","status":"affected","version":"23.10.0","versionType":"semver"},{"lessThan":"23.04.27","status":"affected","version":"23.04.0","versionType":"semver"},{"lessThan":"22.10.29","status":"affected","version":"22.10.0","versionType":"semver"}],"platforms":[]}],"packages":[],"cwes":["CWE-79"],"aliases":[],"references":[{"url":"https://thewatch.centreon.com/latest-security-bulletins-64/cve-2024-55574-centreon-web-high-severity-4435","tags":["vendor-advisory","Vendor Advisory","advisory"]},{"url":"https://github.com/centreon/centreon/releases","tags":["release-notes","Release Notes","advisory"]},{"url":"https://github.com/CVEProject/cvelistV5/tree/main/cves/2025/4xxx/CVE-2025-4647.json","tags":["advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-4647","tags":["advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00288,"epssPercentile":0.21775,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-4647","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-4647","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-4647","ok":true,"note":"0 packages"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-4647","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}