{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-40767","id":"CVE-2025-40767","title":"SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0): gain elevated access","description":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application runs docker containers without adequate security controls to enforce isolation. This could allow an attacker to gain elevated access, potentially accessing sensitive host system resources.","descriptionLong":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application runs docker containers without adequate security controls to enforce isolation. This could allow an attacker to gain elevated access, potentially accessing sensitive host system resources.","published":"2025-08-12T11:17:17.311Z","updated":"2026-06-17T09:22:06.113Z","reserved":"2025-04-16T08:39:30.032Z","status":"Analyzed","rejected":false,"assigner":"siemens","metric":{"version":"4.0","score":8.8,"vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","rating":"high","source":"siemens"},"metrics":[{"version":"4.0","score":8.8,"vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","rating":"high","source":"siemens"},{"version":"4.0","score":8.8,"vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"siemens.com"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H","rating":"high","source":"siemens"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H","rating":"high","source":"siemens.com"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"}],"rating":"high","products":["Siemens SINEC Traffic Analyzer"],"affectedProducts":[{"vendor":"Siemens","product":"SINEC Traffic Analyzer","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-250"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-517338.html","tags":["Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00149,"epssPercentile":0.04156,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-40767","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-40767","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-40767","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-40767","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}