{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-40555","id":"CVE-2025-40555","title":"APOGEE PXC+TALON TC Series (BACnet) (All versions): residing in the same BACnet network to send a specially crafted m…","description":"A vulnerability has been identified in APOGEE PXC+TALON TC Series (BACnet) (All versions). Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the targeted device, and ","descriptionLong":"A vulnerability has been identified in APOGEE PXC+TALON TC Series (BACnet) (All versions). Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the targeted device, and potentially reduce the availability of BACnet network. A power cycle is required to restore the device's normal operation.","published":"2025-05-13T09:38:50.440Z","updated":"2026-06-17T09:21:44.910Z","reserved":"2025-04-16T08:20:17.029Z","status":"Deferred","rejected":false,"assigner":"siemens","metric":{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:L","rating":"medium","source":"siemens"},"metrics":[{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:L","rating":"medium","source":"siemens"},{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"medium","source":"siemens.com"},{"version":"3.1","score":4.7,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L","rating":"medium","source":"siemens"},{"version":"3.1","score":4.7,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L","rating":"medium","source":"siemens.com"}],"rating":"medium","products":["Siemens APOGEE PXC+TALON TC Series (BACnet)"],"affectedProducts":[{"vendor":"Siemens","product":"APOGEE PXC+TALON TC Series (BACnet)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-440"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-718393.html","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00219,"epssPercentile":0.12507,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-40555","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-40555","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-40555","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-40555","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}