{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-3020","id":"CVE-2025-3020","title":"Wiesemann & Theis: Multiple W&T Products are vulnerable to cross-site-scripting","description":"An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact.","descriptionLong":"An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact.","published":"2025-05-06T08:01:58.965Z","updated":"2026-06-17T09:19:02.180Z","reserved":"2025-03-31T06:31:36.670Z","status":"Deferred","rejected":false,"assigner":"CERTVDE","metric":{"version":"3.1","score":5.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N","rating":"medium","source":"CERTVDE"},"metrics":[{"version":"3.1","score":5.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N","rating":"medium","source":"CERTVDE"},{"version":"3.1","score":5.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N","rating":"medium","source":"cert.vde.com"}],"rating":"medium","products":["Wiesemann & Theis ERP-Gateway 12x Digital Input, 6x Digital Relais","Wiesemann & Theis ERP-Gateway 2x Digital Input, 2x Digital Output","Wiesemann & Theis ERP-Gateway 2x Digital PoE","Wiesemann & Theis Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital","Wiesemann & Theis Web-Count 6x Digital","Wiesemann & Theis Web-Graph Air Quality","Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relais","Wiesemann & Theis Web-IO Analog-In/Out 2x 0/4..20mA PoE","Wiesemann & Theis Web-IO Digital 12xIn, 12xOut","Wiesemann & Theis Web-IO Digital 12xIn, 12xOut, 1xRS232","Wiesemann & Theis Web-IO Digital 2xIn, 2xOut","Wiesemann & Theis Web-IO Digital Logger 6xIn, 6xOut","Wiesemann & Theis Web-Thermograph 2x","Wiesemann & Theis Web-Thermograph 8x","Wiesemann & Theis Web-Thermograph NTC","Wiesemann & Theis Web-Thermograph NTC PoE","Wiesemann & Theis Web-Thermograph Pt100 / Pt1000","Wiesemann & Theis Web-Thermograph Pt100 / Pt1000 PoE","Wiesemann & Theis Web-Thermograph Relais","Wiesemann & Theis Web-Thermo-Hygrobarograph","Wiesemann & Theis Web-Thermo-Hygrograph"],"affectedProducts":[{"vendor":"Wiesemann & Theis","product":"ERP-Gateway 12x Digital Input, 6x Digital Relais","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"ERP-Gateway 2x Digital Input, 2x Digital Output","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"ERP-Gateway 2x Digital PoE","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Count 6x Digital","defaultStatus":"unaffected","versions":[{"lessThan":"3.79","status":"affected","version":"0","versionType":"semver"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Graph Air Quality","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO 12x Digital Input, 6x Digital Relais","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO 12x Digital Input, 6x Digital Relais","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO 12x Digital Input, 6x Digital Relais","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO Analog-In/Out 2x 0/4..20mA PoE","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO Digital 12xIn, 12xOut","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO Digital 12xIn, 12xOut","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO Digital 12xIn, 12xOut","defaultStatus":"unaffected","versions":[{"lessThan":"4.08","status":"affected","version":"0","versionType":"semver"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO Digital 12xIn, 12xOut, 1xRS232","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO Digital 12xIn, 12xOut, 1xRS232","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO Digital 2xIn, 2xOut","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO Digital 2xIn, 2xOut","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO Digital 2xIn, 2xOut","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-IO Digital Logger 6xIn, 6xOut","defaultStatus":"unaffected","versions":[{"lessThan":"3.70","status":"affected","version":"0","versionType":"semver"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Thermograph 2x","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Thermograph 8x","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Thermograph NTC","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Thermograph NTC PoE","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Thermograph Pt100 / Pt1000","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Thermograph Pt100 / Pt1000 PoE","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Thermograph Relais","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Thermo-Hygrobarograph","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]},{"vendor":"Wiesemann & Theis","product":"Web-Thermo-Hygrograph","defaultStatus":"unaffected","versions":[{"status":"affected","version":"all"}],"platforms":[]}],"packages":[],"cwes":["CWE-79"],"aliases":[],"references":[{"url":"https://cert.vde.com/en/advisories/VDE-2025-032","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00289,"epssPercentile":0.21808,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-3020","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-3020","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-3020","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-3020","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}