{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-2441","id":"CVE-2025-2441","title":"CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of confi…","description":"CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of\nconfidentiality when a malicious user, having physical access, sets the radio in factory default mode where the\nproduct does not correctly initialize all data.","descriptionLong":"CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of\nconfidentiality when a malicious user, having physical access, sets the radio in factory default mode where the\nproduct does not correctly initialize all data.","published":"2025-04-09T10:23:45.536Z","updated":"2026-06-17T09:07:00.133Z","reserved":"2025-03-17T16:00:19.880Z","status":"Deferred","rejected":false,"assigner":"schneider","metric":{"version":"4.0","score":4.1,"vector":"CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","rating":"medium","source":"schneider"},"metrics":[{"version":"4.0","score":4.1,"vector":"CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","rating":"medium","source":"schneider"},{"version":"4.0","score":4.1,"vector":"CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"medium","source":"se.com"},{"version":"3.1","score":4.6,"vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","rating":"medium","source":"schneider"},{"version":"3.1","score":4.6,"vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","rating":"medium","source":"se.com"}],"rating":"medium","products":["Schneider Electric Trio Q Licensed Data Radio"],"affectedProducts":[{"vendor":"Schneider Electric","product":"Trio Q Licensed Data Radio","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions prior to v2.7.2"}],"platforms":[]}],"packages":[],"cwes":["CWE-1188"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-098-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-098-02.pdf","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.0023,"epssPercentile":0.13948,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-2441","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-2441","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-2441","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-2441","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}