{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-13905","id":"CVE-2025-13905","title":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse…","description":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause  privilege escalation through the reverse shell when  one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.","descriptionLong":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause  privilege escalation through the reverse shell when  one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.","published":"2026-01-29T15:20:45.864Z","updated":"2026-06-17T08:34:57.447Z","reserved":"2025-12-02T16:35:40.124Z","status":"Deferred","rejected":false,"assigner":"schneider","metric":{"version":"4.0","score":7,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"schneider"},"metrics":[{"version":"4.0","score":7,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"schneider"},{"version":"4.0","score":7,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"se.com"}],"rating":"high","products":["Schneider Electric EcoStruxure™ Process Expert","Schneider Electric EcoStruxure™ Process Expert for AVEVA System Platform"],"affectedProducts":[{"vendor":"Schneider Electric","product":"EcoStruxure™ Process Expert","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions prior to 2025"}],"platforms":[]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Process Expert for AVEVA System Platform","defaultStatus":"unaffected","versions":[{"status":"affected","version":"All versions"}],"platforms":[]}],"packages":[],"cwes":["CWE-276"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-02.pdf","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00112,"epssPercentile":0,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-13905","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-13905","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-13905","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-13905","ok":true,"note":"scored "}],"aiTitle":false,"tech":[],"critical":[],"attention":null}