{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2025-1204","id":"CVE-2025-1204","title":"The \"update\" binary in the firmware of the affected product sends attempts to mount to a hard-coded, routable IP addr…","description":"The \"update\" binary in the firmware of the affected product sends attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function triggers if the 'C' button is pressed at a specific time during the boot process. If an attacker is able to control or impersonate this IP address, they could upload and overwrite files on the device.","descriptionLong":"The \"update\" binary in the firmware of the affected product sends attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function triggers if the 'C' button is pressed at a specific time during the boot process. If an attacker is able to control or impersonate this IP address, they could upload and overwrite files on the device.","published":"2025-02-25T17:00:16.133Z","updated":"2026-06-17T08:38:35.903Z","reserved":"2025-02-10T17:00:02.210Z","status":"Deferred","rejected":false,"assigner":"icscert","metric":{"version":"4.0","score":7.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"icscert"},"metrics":[{"version":"4.0","score":7.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"icscert"},{"version":"4.0","score":7.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"hq.dhs.gov"}],"rating":"high","products":["Contec Health CMS8000 Patient Monitor"],"affectedProducts":[{"vendor":"Contec Health","product":"CMS8000 Patient Monitor","defaultStatus":"unaffected","versions":[{"status":"affected","version":"0"}],"platforms":[]}],"packages":[],"cwes":["CWE-912"],"aliases":[],"references":[{"url":"https://claroty.com/team82/research/are-contec-cms8000-patient-monitors-infected-with-a-chinese-backdoor-the-reality-is-more-complicated?ref=vault33.org","tags":["third-party-advisory"]},{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-030-01","tags":["government-resource"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"total"},"epss":0.00483,"epssPercentile":0.42399,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2025-1204","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2025-1204","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2025-1204","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2025-1204","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}