{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-9409","id":"CVE-2024-9409","title":"CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive…","description":"CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.","descriptionLong":"CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.","published":"2024-11-13T04:29:01.040Z","updated":"2026-06-17T08:24:31.077Z","reserved":"2024-10-01T12:08:25.066Z","status":"Analyzed","rejected":false,"assigner":"schneider","metric":{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"schneider"},"metrics":[{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"schneider"},{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"se.com"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"schneider"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"se.com"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"NVD"}],"rating":"high","products":["Schneider Electric PowerLogic PM5320","Schneider Electric PowerLogic PM5340","Schneider Electric PowerLogic PM5341"],"affectedProducts":[{"vendor":"Schneider Electric","product":"PowerLogic PM5320","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 2.3.8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"PowerLogic PM5340","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 2.3.8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"PowerLogic PM5341","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 2.6.6 and prior"}],"platforms":[]}],"packages":[],"cwes":["CWE-400"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/doc/SEVD-2024-317-01/SEVD-2024-317-01.pdf","tags":["Mitigation","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial"},"epss":0.00816,"epssPercentile":0.57803,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-9409","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-9409","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-9409","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-9409","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}