{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-5560","id":"CVE-2024-5560","title":"CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface whe…","description":"CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice’s web interface when an attacker sends a specially crafted HTTP request.","descriptionLong":"CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice’s web interface when an attacker sends a specially crafted HTTP request.","published":"2024-06-12T16:45:56.256Z","updated":"2026-06-17T08:16:11.740Z","reserved":"2024-05-31T06:58:55.638Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","rating":"medium","source":"schneider"},"metrics":[{"version":"3.1","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","rating":"medium","source":"schneider"},{"version":"3.1","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","rating":"medium","source":"se.com"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"NVD"}],"rating":"medium","products":["Schneider Electric Sage 1410","Schneider Electric Sage 1430","Schneider Electric Sage 1450","Schneider Electric Sage 2400","Schneider Electric Sage 3030 Magnum","Schneider Electric Sage 4400"],"affectedProducts":[{"vendor":"Schneider Electric","product":"Sage 1410","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Sage 1430","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Sage 1450","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Sage 2400","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Sage 3030 Magnum","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Sage 4400","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]}],"packages":[],"cwes":["CWE-125"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf","tags":["x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial"},"epss":0.00894,"epssPercentile":0.60237,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-5560","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-5560","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-5560","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-5560","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}