{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-54092","id":"CVE-2024-54092","title":"Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Ind…","description":"A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versi","descriptionLong":"A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user.","published":"2025-04-08T08:22:24.861Z","updated":"2026-06-17T08:09:45.300Z","reserved":"2024-11-28T13:06:14.569Z","status":"Deferred","rejected":false,"assigner":"siemens","metric":{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"critical","source":"siemens"},"metrics":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"critical","source":"siemens"},{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"critical","source":"siemens.com"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"siemens"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"siemens.com"}],"rating":"critical","products":["Siemens Industrial Edge Device Kit - arm64 V1.17","Siemens Industrial Edge Device Kit - arm64 V1.18","Siemens Industrial Edge Device Kit - arm64 V1.19","Siemens Industrial Edge Device Kit - arm64 V1.20","Siemens Industrial Edge Device Kit - arm64 V1.21","Siemens Industrial Edge Device Kit - x86-64 V1.17","Siemens Industrial Edge Device Kit - x86-64 V1.18","Siemens Industrial Edge Device Kit - x86-64 V1.19","Siemens Industrial Edge Device Kit - x86-64 V1.20","Siemens Industrial Edge Device Kit - x86-64 V1.21","Siemens Industrial Edge Own Device (IEOD)","Siemens Industrial Edge Virtual Device","Siemens SCALANCE LPE9413","Siemens SIMATIC IPC BX-39A Industrial Edge Device","Siemens SIMATIC IPC BX-59A Industrial Edge Device","Siemens SIMATIC IPC127E Industrial Edge Device","Siemens SIMATIC IPC227E Industrial Edge Device","Siemens SIMATIC IPC427E Industrial Edge Device","Siemens SIMATIC IPC847E Industrial Edge Device"],"affectedProducts":[{"vendor":"Siemens","product":"Industrial Edge Device Kit - arm64 V1.17","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Device Kit - arm64 V1.18","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Device Kit - arm64 V1.19","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Device Kit - arm64 V1.20","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V1.20.2-1","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Device Kit - arm64 V1.21","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V1.21.1-1","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Device Kit - x86-64 V1.17","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Device Kit - x86-64 V1.18","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Device Kit - x86-64 V1.19","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Device Kit - x86-64 V1.20","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V1.20.2-1","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Device Kit - x86-64 V1.21","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V1.21.1-1","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Own Device (IEOD)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V1.21.1-1-a","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Industrial Edge Virtual Device","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V1.21.1-1-a","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE LPE9413","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.1","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC IPC BX-39A Industrial Edge Device","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC IPC BX-59A Industrial Edge Device","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC IPC127E Industrial Edge Device","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC IPC227E Industrial Edge Device","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC IPC427E Industrial Edge Device","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC IPC847E Industrial Edge Device","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-1390"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-634640.html","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-819629.html","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total"},"epss":0.0077,"epssPercentile":0.56403,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-54092","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-54092","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-54092","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-54092","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}