{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-52961","id":"CVE-2024-52961","title":"An improper neutralization of special elements used in an OS Command vulnerability [CWE-78] vulnerability in Fortinet…","description":"An improper neutralization of special elements used in an OS Command vulnerability [CWE-78] vulnerability in Fortinet FortiSandbox 5.0.0, FortiSandbox 4.4.0 through 4.4.6, FortiSandbox 4.2.1 through 4.2.7, FortiSandbox 4.0.0 through 4.0.5, FortiSandbox 3.2 all versions, FortiSandbox 3.1 all versions, FortiSandbox 3.0 all versions allows an authenticated attacker with at least read-only permission ","descriptionLong":"An improper neutralization of special elements used in an OS Command vulnerability [CWE-78] vulnerability in Fortinet FortiSandbox 5.0.0, FortiSandbox 4.4.0 through 4.4.6, FortiSandbox 4.2.1 through 4.2.7, FortiSandbox 4.0.0 through 4.0.5, FortiSandbox 3.2 all versions, FortiSandbox 3.1 all versions, FortiSandbox 3.0 all versions allows an authenticated attacker with at least read-only permission to execute unauthorized commands via crafted requests.","published":"2025-03-11T14:54:30.498Z","updated":"2026-06-17T08:07:55.847Z","reserved":"2024-11-18T13:36:52.464Z","status":"Modified","rejected":false,"assigner":"fortinet","metric":{"version":"3.1","score":8.6,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:X/RC:C","rating":"high","source":"fortinet"},"metrics":[{"version":"3.1","score":8.6,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:X/RC:C","rating":"high","source":"fortinet"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"fortinet.com"}],"rating":"high","products":["Fortinet FortiSandbox"],"affectedProducts":[{"vendor":"Fortinet","product":"FortiSandbox","defaultStatus":"unaffected","versions":[{"version":"5.0.0","status":"affected"},{"versionType":"semver","version":"4.4.0","lessThanOrEqual":"4.4.6","status":"affected"},{"versionType":"semver","version":"4.2.1","lessThanOrEqual":"4.2.7","status":"affected"},{"versionType":"semver","version":"4.0.0","lessThanOrEqual":"4.0.5","status":"affected"},{"versionType":"semver","version":"3.2.0","lessThanOrEqual":"3.2.4","status":"affected"},{"versionType":"semver","version":"3.1.0","lessThanOrEqual":"3.1.5","status":"affected"},{"versionType":"semver","version":"3.0.0","lessThanOrEqual":"3.0.7","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-78"],"aliases":[],"references":[{"url":"https://fortiguard.fortinet.com/psirt/FG-IR-24-306","tags":["Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00548,"epssPercentile":0.46802,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-52961","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-52961","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-52961","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-52961","ok":true,"note":"scored 2026-11-20"}],"aiTitle":false,"tech":["fortinet"],"critical":[],"attention":null}