{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-4872","id":"CVE-2024-4872","title":"the query validation of the MicroSCADA Pro/X SYS600 product: inject code towards persistent data","description":"A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability\nan attacker must have a valid credential.","descriptionLong":"A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability\nan attacker must have a valid credential.","published":"2024-08-27T12:37:28.958Z","updated":"2026-06-17T08:03:04.760Z","reserved":"2024-05-14T14:41:23.177Z","status":"Analyzed","rejected":false,"assigner":"Hitachi Energy","metric":{"version":"3.1","score":9.9,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"Hitachi Energy"},"metrics":[{"version":"3.1","score":9.9,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"Hitachi Energy"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","rating":"high","source":"Hitachi Energy"},{"version":"3.1","score":9.9,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"hitachienergy.com"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"}],"rating":"critical","products":["Hitachi Energy MicroSCADA X SYS600","Hitachi Energy MicroSCADA Pro SYS600"],"affectedProducts":[{"vendor":"Hitachi Energy","product":"MicroSCADA X SYS600","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"10.5","status":"affected","version":"10.0","versionType":"custom"},{"status":"unaffected","version":"10.3 vulnerability patch 2025_01","versionType":"custom"},{"status":"unaffected","version":"10.4 vulnerability patch 2025_01","versionType":"custom"},{"status":"unaffected","version":"10.5 vulnerability patch 2025_01","versionType":"custom"}],"platforms":[]},{"vendor":"Hitachi Energy","product":"MicroSCADA Pro SYS600","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"9.4 FP2 HF5","status":"affected","version":"9.4 FP2 HF1","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-943"],"aliases":[],"references":[{"url":"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["vendor-advisory","Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.005,"epssPercentile":0.43527,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-4872","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-4872","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-4872","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-4872","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}