{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-46892","id":"CVE-2024-46892","title":"SINEC INS (All versions < V1.0 SP2 Update 3): continue performing malicious actions even after their user account ha","description":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly invalidate sessions when the associated user is deleted or disabled or their permissions are modified. This could allow an authenticated attacker to continue performing malicious actions even after their user account has been disabled.","descriptionLong":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly invalidate sessions when the associated user is deleted or disabled or their permissions are modified. This could allow an authenticated attacker to continue performing malicious actions even after their user account has been disabled.","published":"2024-11-12T12:49:44.470Z","updated":"2026-06-17T07:56:09.497Z","reserved":"2024-09-12T11:24:19.243Z","status":"Analyzed","rejected":false,"assigner":"siemens","metric":{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","rating":"medium","source":"siemens"},"metrics":[{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","rating":"medium","source":"siemens"},{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"medium","source":"siemens.com"},{"version":"3.1","score":4.9,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C","rating":"medium","source":"siemens"},{"version":"3.1","score":4.9,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N","rating":"medium","source":"siemens.com"},{"version":"3.1","score":8.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","rating":"high","source":"NVD"}],"rating":"medium","products":["Siemens SINEC INS"],"affectedProducts":[{"vendor":"Siemens","product":"SINEC INS","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V1.0 SP2 Update 3","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-613"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-915275.html","tags":["Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00296,"epssPercentile":0.22631,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-46892","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-46892","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-46892","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-46892","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}