{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-43652","id":"CVE-2024-43652","title":"Authenticated command injection in the <redacted> action leads to full remote code execution as root on the charging station","description":"Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701\n\nLikelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by ","descriptionLong":"Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701\n\nLikelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.","published":"2025-01-09T07:56:46.379Z","updated":"2026-06-17T07:51:29.830Z","reserved":"2024-08-14T09:27:41.767Z","status":"Deferred","rejected":false,"assigner":"DIVD","metric":{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y/R:U/V:D/RE:M","rating":"critical","source":"DIVD"},"metrics":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y/R:U/V:D/RE:M","rating":"critical","source":"DIVD"},{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:Y/R:U/V:D/RE:M/U:X","rating":"critical","source":"divd.nl"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"CISA-ADP"}],"rating":"critical","products":["Iocharger firmware for AC chargers"],"affectedProducts":[{"vendor":"Iocharger","product":"Iocharger firmware for AC chargers","defaultStatus":"unaffected","versions":[{"lessThan":"24120701","status":"affected","version":"0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-78","CWE-250"],"aliases":[],"references":[{"url":"https://csirt.divd.nl/DIVD-2024-00035/","tags":["third-party-advisory"]},{"url":"https://csirt.divd.nl/CVE-2024-43652/","tags":["third-party-advisory"]},{"url":"https://iocharger.com","tags":["product"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.01992,"epssPercentile":0.81111,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-43652","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-43652","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-43652","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-43652","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}