{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-4241","id":"CVE-2024-4241","title":"Tenda W9 formQosManageDouble_auto stack-based overflow","description":"A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respo","descriptionLong":"A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","published":"2024-04-26T21:00:05.152Z","updated":"2026-06-17T08:01:30.380Z","reserved":"2024-04-26T12:40:13.280Z","status":"Analyzed","rejected":false,"assigner":"VulDB","metric":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"VulDB"},"metrics":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"VulDB"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"vuldb.com"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"},{"version":"3.0","score":8.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"VulDB"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","rating":"critical","source":"VulDB"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","rating":"critical","source":"vuldb.com"}],"rating":"high","products":["Tenda W9"],"affectedProducts":[{"vendor":"Tenda","product":"W9","defaultStatus":null,"versions":[{"version":"1.0.0.7(4456)","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-121","CWE-787"],"aliases":[],"references":[{"url":"https://vuldb.com/?id.262132","tags":["vdb-entry","technical-description","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?ctiid.262132","tags":["signature","permissions-required","x_transferred","Permissions Required","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?submit.319823","tags":["third-party-advisory","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formQosManageDouble_user.md","tags":["related","x_transferred","Broken Link"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial"},"epss":0.01347,"epssPercentile":0.72048,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-4241","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-4241","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-4241","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-4241","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}