{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-41908","id":"CVE-2024-41908","title":"NX (All versions < V2406.3000): crash the application or execute code in the context of the current pr","description":"A vulnerability has been identified in NX (All versions < V2406.3000). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.","descriptionLong":"A vulnerability has been identified in NX (All versions < V2406.3000). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.","published":"2024-08-13T07:54:28.985Z","updated":"2026-06-17T07:48:25.863Z","reserved":"2024-07-23T12:40:56.886Z","status":"Deferred","rejected":false,"assigner":"siemens","metric":{"version":"4.0","score":7.3,"vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"siemens"},"metrics":[{"version":"4.0","score":7.3,"vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"siemens"},{"version":"4.0","score":7.3,"vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"siemens.com"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"siemens"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"siemens.com"}],"rating":"high","products":["Siemens NX"],"affectedProducts":[{"vendor":"Siemens","product":"NX","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2406.3000","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-125"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-357412.html","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00182,"epssPercentile":0.07891,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-41908","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-41908","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-41908","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-41908","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}