{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-4065","id":"CVE-2024-4065","title":"Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow","description":"A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability ","descriptionLong":"A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","published":"2024-04-23T20:00:07.093Z","updated":"2026-06-17T08:01:02.177Z","reserved":"2024-04-23T13:22:21.928Z","status":"Analyzed","rejected":false,"assigner":"VulDB","metric":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"VulDB"},"metrics":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"VulDB"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"vuldb.com"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"},{"version":"3.0","score":8.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"VulDB"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","rating":"critical","source":"VulDB"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","rating":"critical","source":"vuldb.com"}],"rating":"high","products":["Tenda AC8"],"affectedProducts":[{"vendor":"Tenda","product":"AC8","defaultStatus":null,"versions":[{"version":"16.03.34.09","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-121","CWE-787"],"aliases":[],"references":[{"url":"https://vuldb.com/?id.261791","tags":["vdb-entry","technical-description","x_transferred","Permissions Required","VDB Entry"]},{"url":"https://vuldb.com/?ctiid.261791","tags":["signature","permissions-required","x_transferred","Permissions Required","VDB Entry"]},{"url":"https://vuldb.com/?submit.316494","tags":["third-party-advisory","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md","tags":["exploit","x_transferred","Exploit","Third Party Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":true,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.01643,"epssPercentile":0.76919,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-4065","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-4065","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-4065","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-4065","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}