{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-39867","id":"CVE-2024-39867","title":"SINEMA Remote Connect Server (All versions < V3.2 SP1): access and edit device configuration information of devices f…","description":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges.","descriptionLong":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges.","published":"2024-07-09T12:05:22.532Z","updated":"2026-06-17T07:42:55.883Z","reserved":"2024-07-01T13:05:40.287Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"siemens"},"metrics":[{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"siemens"},{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"siemens.com"},{"version":"3.1","score":7.6,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C","rating":"high","source":"siemens"},{"version":"3.1","score":7.6,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H","rating":"high","source":"siemens.com"},{"version":"3.1","score":7.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","rating":"high","source":"NVD"}],"rating":"high","products":["Siemens SINEMA Remote Connect Server"],"affectedProducts":[{"vendor":"Siemens","product":"SINEMA Remote Connect Server","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.2 SP1","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-425"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-381581.html","tags":["x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00361,"epssPercentile":0.30548,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-39867","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-39867","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-39867","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-39867","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}