{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-37037","id":"CVE-2024-37037","title":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that coul…","description":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path\nTraversal’) vulnerability exists that could allow an authenticated user with access to the device’s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest.","descriptionLong":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path\nTraversal’) vulnerability exists that could allow an authenticated user with access to the device’s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest.","published":"2024-06-12T16:50:09.159Z","updated":"2026-06-17T07:37:38.887Z","reserved":"2024-05-31T06:52:05.762Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":8.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","rating":"high","source":"schneider"},"metrics":[{"version":"3.1","score":8.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","rating":"high","source":"schneider"},{"version":"3.1","score":8.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","rating":"high","source":"se.com"},{"version":"3.1","score":8.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","rating":"high","source":"NVD"}],"rating":"high","products":["Schneider Electric Sage 1410","Schneider Electric Sage 1430","Schneider Electric Sage 1450","Schneider Electric Sage 2400","Schneider Electric Sage 3030 Magnum","Schneider Electric Sage 4400"],"affectedProducts":[{"vendor":"Schneider Electric","product":"Sage 1410","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Sage 1430","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Sage 1450","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Sage 2400","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Sage 3030 Magnum","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Sage 4400","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}],"platforms":[]}],"packages":[],"cwes":["CWE-22"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf","tags":["x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.01025,"epssPercentile":0.64229,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-37037","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-37037","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-37037","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-37037","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}