{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-2894","id":"CVE-2024-2894","title":"Tenda AC7 SetNetControlList formSetQosBand stack-based overflow","description":"A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this","descriptionLong":"A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","published":"2024-03-26T17:00:07.831Z","updated":"2026-06-17T07:25:46.273Z","reserved":"2024-03-26T09:25:39.103Z","status":"Analyzed","rejected":false,"assigner":"VulDB","metric":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"VulDB"},"metrics":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"VulDB"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"vuldb.com"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"},{"version":"3.0","score":8.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"VulDB"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","rating":"critical","source":"VulDB"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","rating":"critical","source":"vuldb.com"}],"rating":"high","products":["Tenda AC7"],"affectedProducts":[{"vendor":"Tenda","product":"AC7","defaultStatus":null,"versions":[{"version":"15.03.06.44","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-121","CWE-787"],"aliases":[],"references":[{"url":"https://vuldb.com/?id.257937","tags":["vdb-entry","technical-description","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?ctiid.257937","tags":["signature","permissions-required","x_transferred","Permissions Required","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?submit.300357","tags":["third-party-advisory","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md","tags":["exploit","x_transferred","Exploit","Third Party Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":true,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"total"},"epss":0.01584,"epssPercentile":0.76098,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-2894","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-2894","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-2894","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-2894","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}