{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-2637","id":"CVE-2024-2637","title":"Insecure Loading of Code in B&R Products","description":"An Uncontrolled Search Path Element vulnerability in B&R Industrial Automation Scene Viewer, B&R Industrial Automation Automation Runtime, B&R Industrial Automation mapp Vision, B&R Industrial Automation mapp View, B&R Industrial Automation mapp Cockpit, B&R Industrial Automation mapp Safety, B&R Industrial Automation VC4, B&R Industrial Automation APROL, B&R Industrial Automation CAN Driver, B&R ","descriptionLong":"An Uncontrolled Search Path Element vulnerability in B&R Industrial Automation Scene Viewer, B&R Industrial Automation Automation Runtime, B&R Industrial Automation mapp Vision, B&R Industrial Automation mapp View, B&R Industrial Automation mapp Cockpit, B&R Industrial Automation mapp Safety, B&R Industrial Automation VC4, B&R Industrial Automation APROL, B&R Industrial Automation CAN Driver, B&R Industrial Automation CAN Driver CC770, B&R Industrial Automation CAN Driver SJA1000, B&R Industrial Automation Tou0ch Lock, B&R Industrial Automation B&R Single-Touch Driver, B&R Industrial Automation Serial User Mode Touch Driver, B&R Industrial Automation Windows Settings Changer (LTSC), B&R Industrial Automation Windows Settings Changer (2019 LTSC), B&R Industrial Automation Windows 10 Recovery Solution, B&R Industrial Automation ADI driver universal, B&R Industrial Automation ADI Development Kit, B&R Industrial Automation ADI .NET SDK, B&R Industrial Automation SRAM driver, B&R Industrial Automation HMI Service Center, B&R Industrial Automation HMI Service Center Maintenance, B&R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0.","published":"2024-05-14T18:49:28.624Z","updated":"2026-06-17T07:24:56.563Z","reserved":"2024-03-19T08:15:24.368Z","status":"Deferred","rejected":false,"assigner":"ABB","metric":{"version":"3.1","score":7.2,"vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"ABB"},"metrics":[{"version":"3.1","score":7.2,"vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"ABB"},{"version":"3.1","score":7.2,"vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"ch.abb.com"}],"rating":"high","products":["B&R Industrial Automation Scene Viewer","B&R Industrial Automation Automation Runtime","B&R Industrial Automation mapp Vision","B&R Industrial Automation mapp View","B&R Industrial Automation mapp Cockpit","B&R Industrial Automation mapp Safety","B&R Industrial Automation VC4","B&R Industrial Automation APROL","B&R Industrial Automation CAN Driver","B&R Industrial Automation CAN Driver CC770","B&R Industrial Automation CAN Driver SJA1000","B&R Industrial Automation Tou0ch Lock","B&R Industrial Automation B&R Single-Touch Driver","B&R Industrial Automation Serial User Mode Touch Driver","B&R Industrial Automation Windows Settings Changer (LTSC)","B&R Industrial Automation Windows Settings Changer (2019 LTSC)","B&R Industrial Automation Windows 10 Recovery Solution","B&R Industrial Automation ADI driver universal","B&R Industrial Automation ADI Development Kit","B&R Industrial Automation ADI .NET SDK","B&R Industrial Automation SRAM driver","B&R Industrial Automation HMI Service Center","B&R Industrial Automation HMI Service Center Maintenance","B&R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC","B&R Industrial Automation KCF Editor"],"affectedProducts":[{"vendor":"B&R Industrial Automation","product":"Scene Viewer","defaultStatus":"unaffected","versions":[{"lessThan":"4.4.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"Automation Runtime","defaultStatus":"unaffected","versions":[{"lessThan":"J4.93","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"mapp Vision","defaultStatus":"unaffected","versions":[{"lessThan":"5.26.1","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"mapp View","defaultStatus":"unaffected","versions":[{"lessThan":"5.24.2","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"mapp Cockpit","defaultStatus":"unaffected","versions":[{"lessThan":"5.24.2","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"mapp Safety","defaultStatus":"unaffected","versions":[{"lessThan":"5.24.2","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"VC4","defaultStatus":"unaffected","versions":[{"lessThan":"4.73.2","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"APROL","defaultStatus":"unaffected","versions":[{"lessThan":"4.4-01","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"CAN Driver","defaultStatus":"unaffected","versions":[{"lessThan":"1.1.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"CAN Driver CC770","defaultStatus":"unaffected","versions":[{"lessThan":"3.3.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"CAN Driver SJA1000","defaultStatus":"unaffected","versions":[{"lessThan":"1.3.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"Tou0ch Lock","defaultStatus":"unaffected","versions":[{"lessThan":"2.1.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"B&R Single-Touch Driver","defaultStatus":"unaffected","versions":[{"lessThan":"2.0.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"Serial User Mode Touch Driver","defaultStatus":"unaffected","versions":[{"lessThan":"1.7.1","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"Windows Settings Changer (LTSC)","defaultStatus":"unaffected","versions":[{"lessThan":"3.2.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"Windows Settings Changer (2019 LTSC)","defaultStatus":"unaffected","versions":[{"lessThan":"2.2.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"Windows 10 Recovery Solution","defaultStatus":"unaffected","versions":[{"lessThan":"3.2.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"ADI driver universal","defaultStatus":"unaffected","versions":[{"lessThan":"3.2.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"ADI Development Kit","defaultStatus":"unaffected","versions":[{"lessThan":"5.5.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"ADI .NET SDK","defaultStatus":"unaffected","versions":[{"lessThan":"4.1.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"SRAM driver","defaultStatus":"unaffected","versions":[{"lessThan":"1.2.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"HMI Service Center","defaultStatus":"unaffected","versions":[{"lessThan":"3.1.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"HMI Service Center Maintenance","defaultStatus":"unaffected","versions":[{"lessThan":"2.1.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"Windows 10 IoT Enterprise 2019 LTSC","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"1.1","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"B&R Industrial Automation","product":"KCF Editor","defaultStatus":"unaffected","versions":[{"lessThan":"1.1.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-427"],"aliases":[],"references":[{"url":"https://www.br-automation.com/fileadmin/SA24P005_Insecure_Loading_of_Code-c7d9e49c.pdf","tags":["x_transferred"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00168,"epssPercentile":0.0611,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-2637","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-2637","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-2637","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-2637","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}