{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-23814","id":"CVE-2024-23814","title":"The integrated ICMP service of the network stack of affected devices can be forced to exhaust its available memory re…","description":"The integrated ICMP service of the network stack of affected devices can be  forced to exhaust its available memory resources when receiving specially crafted messages targeting IP fragment re-assembly. This could allow an unauthenticated remote attacker to cause a temporary denial of service condition of the ICMP service, other communication services are not affected. Affected devices will resume","descriptionLong":"The integrated ICMP service of the network stack of affected devices can be  forced to exhaust its available memory resources when receiving specially crafted messages targeting IP fragment re-assembly. This could allow an unauthenticated remote attacker to cause a temporary denial of service condition of the ICMP service, other communication services are not affected. Affected devices will resume normal operation after the attack terminates.","published":"2025-02-11T10:28:33.403Z","updated":"2026-06-17T07:13:39.397Z","reserved":"2024-01-22T17:44:56.763Z","status":"Deferred","rejected":false,"assigner":"siemens","metric":{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N","rating":"medium","source":"siemens"},"metrics":[{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N","rating":"medium","source":"siemens"},{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"medium","source":"siemens.com"},{"version":"3.1","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C","rating":"medium","source":"siemens"},{"version":"3.1","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","rating":"medium","source":"siemens.com"}],"rating":"medium","products":["Siemens SIDOOR ATD430W","Siemens SIDOOR ATE530G COATED","Siemens SIDOOR ATE530S COATED","Siemens SIMATIC CFU DIQ","Siemens SIMATIC CFU PA","Siemens SIMATIC ET 200AL IM 157-1 PN","Siemens SIMATIC ET 200M IM 153-4 PN IO HF","Siemens SIMATIC ET 200M IM 153-4 PN IO ST","Siemens SIMATIC ET 200MP IM 155-5 PN BA","Siemens SIMATIC ET 200MP IM 155-5 PN HF","Siemens SIMATIC ET 200MP IM 155-5 PN ST","Siemens SIMATIC ET 200pro IM 154-3 PN HF","Siemens SIMATIC ET 200pro IM 154-4 PN HF","Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU","Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU","Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU","Siemens SIMATIC ET 200S IM 151-3 PN FO","Siemens SIMATIC ET 200S IM 151-3 PN HF","Siemens SIMATIC ET 200S IM 151-3 PN HS","Siemens SIMATIC ET 200S IM 151-3 PN ST","Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU","Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU","Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN","Siemens SIMATIC ET 200SP CPU 1510SP-1 PN","Siemens SIMATIC ET 200SP CPU 1512SP F-1 PN","Siemens SIMATIC ET 200SP CPU 1512SP-1 PN","Siemens SIMATIC ET 200SP IM 155-6 MF HF","Siemens SIMATIC ET 200SP IM 155-6 PN BA","Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)","Siemens SIMATIC ET 200SP IM 155-6 PN HF","Siemens SIMATIC ET 200SP IM 155-6 PN HS","Siemens SIMATIC ET 200SP IM 155-6 PN ST","Siemens SIMATIC ET 200SP IM 155-6 PN ST BA","Siemens SIMATIC ET 200SP IM 155-6 PN/2 HF","Siemens SIMATIC ET 200SP IM 155-6 PN/3 HF","Siemens SIMATIC PN/PN Coupler","Siemens SIMATIC Power Line Booster PLB, Base Module","Siemens SIMATIC Power Line Booster PLB, Modem Module ST","Siemens SIMATIC S7-1200 CPU 1211C AC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1211C DC/DC/DC","Siemens SIMATIC S7-1200 CPU 1211C DC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1212C AC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1212C DC/DC/DC","Siemens SIMATIC S7-1200 CPU 1212C DC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1212FC DC/DC/DC","Siemens SIMATIC S7-1200 CPU 1212FC DC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1214C AC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1214C DC/DC/DC","Siemens SIMATIC S7-1200 CPU 1214C DC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1214FC DC/DC/DC","Siemens SIMATIC S7-1200 CPU 1214FC DC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1215C AC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1215C DC/DC/DC","Siemens SIMATIC S7-1200 CPU 1215C DC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1215FC DC/DC/DC","Siemens SIMATIC S7-1200 CPU 1215FC DC/DC/Rly","Siemens SIMATIC S7-1200 CPU 1217C DC/DC/DC","Siemens SIMATIC S7-1500 CPU 1511-1 PN","Siemens SIMATIC S7-1500 CPU 1511F-1 PN","Siemens SIMATIC S7-1500 CPU 1513-1 PN","Siemens SIMATIC S7-1500 CPU 1513F-1 PN","Siemens SIMATIC S7-1500 CPU 1515-2 PN","Siemens SIMATIC S7-1500 CPU 1515F-2 PN","Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP","Siemens SIMATIC S7-300 CPU 314C-2 PN/DP","Siemens SIMATIC S7-300 CPU 315-2 PN/DP","Siemens SIMATIC S7-300 CPU 315F-2 PN/DP","Siemens SIMATIC S7-300 CPU 315T-3 PN/DP","Siemens SIMATIC S7-300 CPU 317-2 PN/DP","Siemens SIMATIC S7-300 CPU 317F-2 PN/DP","Siemens SIMATIC S7-300 CPU 317T-3 PN/DP","Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP","Siemens SIMATIC S7-300 CPU 319-3 PN/DP","Siemens SIMATIC S7-300 CPU 319F-3 PN/DP","Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)","Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","Siemens SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)","Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)","Siemens SIMATIC TDC CP51M1","Siemens SIMATIC TDC CPU555","Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)","Siemens SIMOCODE pro V PROFINET","Siemens SINUMERIK 840D sl","Siemens SIPLUS ET 200M IM 153-4 PN IO HF","Siemens SIPLUS ET 200M IM 153-4 PN IO ST","Siemens SIPLUS ET 200MP IM 155-5 PN HF","Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL","Siemens SIPLUS ET 200MP IM 155-5 PN ST","Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL","Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU","Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU","Siemens SIPLUS ET 200S IM151-3 PN HF","Siemens SIPLUS ET 200S IM151-3 PN ST","Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN","Siemens SIPLUS ET 200SP IM 155-6 PN HF","Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","Siemens SIPLUS ET 200SP IM 155-6 PN HF TX RAIL","Siemens SIPLUS ET 200SP IM 155-6 PN ST","Siemens SIPLUS ET 200SP IM 155-6 PN ST BA","Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","Siemens SIPLUS HCS4200 CIM4210","Siemens SIPLUS HCS4200 CIM4210C","Siemens SIPLUS HCS4300 CIM4310","Siemens SIPLUS NET PN/PN Coupler","Siemens SIPLUS S7-1200 CPU 1212 AC/DC/RLY","Siemens SIPLUS S7-1200 CPU 1212 DC/DC/RLY","Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC","Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL","Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLY","Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DC","Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLY","Siemens SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL","Siemens SIPLUS S7-1200 CPU 1214FC DC/DC/DC","Siemens SIPLUS S7-1200 CPU 1214FC DC/DC/RLY","Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLY","Siemens SIPLUS S7-1200 CPU 1215 DC/DC/DC","Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLY","Siemens SIPLUS S7-1200 CPU 1215C DC/DC/DC","Siemens SIPLUS S7-1200 CPU 1215FC DC/DC/DC","Siemens SIPLUS S7-1500 CPU 1511-1 PN","Siemens SIPLUS S7-1500 CPU 1511F-1 PN","Siemens SIPLUS S7-1500 CPU 1513-1 PN","Siemens SIPLUS S7-1500 CPU 1513F-1 PN","Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP","Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP","Siemens SIPLUS S7-300 CPU 314C-2 PN/DP","Siemens SIPLUS S7-300 CPU 315-2 PN/DP","Siemens SIPLUS S7-300 CPU 315F-2 PN/DP","Siemens SIPLUS S7-300 CPU 317-2 PN/DP","Siemens SIPLUS S7-300 CPU 317F-2 PN/DP","Siemens SIWAREX WP231","Siemens SIWAREX WP241","Siemens SIWAREX WP251","Siemens SIWAREX WP521 ST","Siemens SIWAREX WP522 ST"],"affectedProducts":[{"vendor":"Siemens","product":"SIDOOR ATD430W","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIDOOR ATE530G COATED","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIDOOR ATE530S COATED","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CFU DIQ","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CFU PA","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CFU PA","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200AL IM 157-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200M IM 153-4 PN IO HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200M IM 153-4 PN IO ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN BA","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-3 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-4 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-8FX PN/DP CPU","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM 151-3 PN FO","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM 151-3 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM 151-3 PN HS","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM 151-3 PN ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM 151-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM 151-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP CPU 1510SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 MF HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN BA","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V1.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN HS","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST BA","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST BA","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN/2 HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN/3 HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC PN/PN Coupler","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V6.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC Power Line Booster PLB, Base Module","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC Power Line Booster PLB, Modem Module ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1211C AC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1211C DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1211C DC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1212C AC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1212C DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1212C DC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1212FC DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1212FC DC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1214C AC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1214C DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1214C DC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1214FC DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1214FC DC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1215C AC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1215C DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1215C DC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1215FC DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1215FC DC/DC/Rly","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1217C DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 314C-2 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315-2 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315F-2 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315T-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317-2 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317F-2 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317T-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317TF-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 319-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 319F-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V10.2","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V8.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC TDC CP51M1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC TDC CPU555","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMOCODE pro V PROFINET","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK 840D sl","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200M IM 153-4 PN IO HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200M IM 153-4 PN IO ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN ST TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN ST TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200S IM 151-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200S IM 151-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200S IM151-3 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200S IM151-3 PN ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS HCS4200 CIM4210","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS HCS4200 CIM4210C","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS HCS4300 CIM4310","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS NET PN/PN Coupler","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V6.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212 AC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212 AC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212 DC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212 DC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212C DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212C DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 AC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 AC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 AC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 DC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 DC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 DC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214FC DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214FC DC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 AC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 AC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 AC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 DC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 DC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 DC/DC/RLY","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215C DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215FC DC/DC/DC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V4.4","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 314C-2 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 315-2 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 315F-2 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 317-2 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 317F-2 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIWAREX WP231","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIWAREX WP241","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIWAREX WP251","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIWAREX WP521 ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIWAREX WP522 ST","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-400"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-769027.html","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-725549.html","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial"},"epss":0.00648,"epssPercentile":0.51856,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-23814","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-23814","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-23814","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-23814","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":["chrome"],"critical":[],"attention":null}