{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-23799","id":"CVE-2024-23799","title":"Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007): The…","description":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.","descriptionLong":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.","published":"2024-02-13T09:00:14.553Z","updated":"2026-06-17T07:13:37.507Z","reserved":"2024-01-22T10:34:49.956Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"3.1","score":3.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C","rating":"low","source":"siemens"},"metrics":[{"version":"3.1","score":3.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C","rating":"low","source":"siemens"},{"version":"3.1","score":3.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L","rating":"low","source":"siemens.com"},{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","rating":"medium","source":"NVD"}],"rating":"low","products":["Siemens Tecnomatix Plant Simulation V2201","Siemens Tecnomatix Plant Simulation V2302"],"affectedProducts":[{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2201","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2302.0007","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-476"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-017796.html","tags":["x_transferred","Mitigation","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.0017,"epssPercentile":0.06438,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-23799","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-23799","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-23799","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-23799","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}