{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-2050","id":"CVE-2024-2050","title":"CWE-79: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’) vulnerability exists whe…","description":"\nCWE-79: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’)\nvulnerability exists when an attacker injects then executes arbitrary malicious JavaScript code\nwithin the context of the product.\n\n","descriptionLong":"\nCWE-79: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’)\nvulnerability exists when an attacker injects then executes arbitrary malicious JavaScript code\nwithin the context of the product.\n\n","published":"2024-03-18T16:04:57.375Z","updated":"2026-06-17T07:23:37.700Z","reserved":"2024-03-01T01:24:55.480Z","status":"Deferred","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":8.2,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N","rating":"high","source":"schneider"},"metrics":[{"version":"3.1","score":8.2,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N","rating":"high","source":"schneider"},{"version":"3.1","score":8.2,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N","rating":"high","source":"se.com"}],"rating":"high","products":["Schneider Electric Easergy T200 (Modbus) Models: T200I, T200E, T200P, T200S, T200H ","Schneider Electric  Easergy T200 (IEC104) Models: T200I, T200E, T200P, T200S, T200H","Schneider Electric  Easergy T200 (DNP3) Models: T200I, T200E, T200P, T200S, T200H"],"affectedProducts":[{"vendor":"Schneider Electric","product":"Easergy T200 (Modbus) Models: T200I, T200E, T200P, T200S, T200H ","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"SC2-04MOD-07000104","versionType":"custom"}],"platforms":[]},{"vendor":"Schneider Electric ","product":"Easergy T200 (IEC104) Models: T200I, T200E, T200P, T200S, T200H","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"SC2-04IEC-07000104","versionType":"custom"}],"platforms":[]},{"vendor":"Schneider Electric ","product":"Easergy T200 (DNP3) Models: T200I, T200E, T200P, T200S, T200H","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"SC2-04DNP-07000104","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-79"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-01.pdf","tags":["x_transferred"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.0047,"epssPercentile":0.41433,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-2050","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-2050","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-2050","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-2050","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}