{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-12248","id":"CVE-2024-12248","title":"Out-of-bounds Write vulnerability in Contec Health CMS8000 Patient Monitor","description":"Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution.","descriptionLong":"Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution.","published":"2025-01-30T18:17:22.814Z","updated":"2026-06-17T06:59:19.877Z","reserved":"2024-12-05T15:20:44.585Z","status":"Deferred","rejected":false,"assigner":"icscert","metric":{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"critical","source":"icscert"},"metrics":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"critical","source":"icscert"},{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"critical","source":"hq.dhs.gov"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"icscert"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"hq.dhs.gov"}],"rating":"critical","products":["Contec Health CMS8000 Patient Monitor"],"affectedProducts":[{"vendor":"Contec Health","product":"CMS8000 Patient Monitor","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Firmware version smart3250-2.6.27-wlan2.1.7.cramfs"},{"status":"affected","version":"Firmware version CMS7.820.075.08/0.74(0.75)"},{"status":"affected","version":"Firmware version CMS7.820.120.01/0.93(0.95)"}],"platforms":[]}],"packages":[],"cwes":["CWE-787"],"aliases":[],"references":[{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-030-01","tags":[]},{"url":"https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total"},"epss":0.0129,"epssPercentile":0.70952,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-12248","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-12248","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-12248","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-12248","ok":true,"note":"scored 2026-11-20"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}