{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2024-10313","id":"CVE-2024-10313","title":"iniNet Solutions SpiderControl SCADA PC HMI Editor Path Traversal","description":"iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal \nvulnerability. When the software loads a malicious ‘ems' project \ntemplate file constructed by an attacker, it can write files to \narbitrary directories. This can lead to overwriting system files, \ncausing system paralysis, or writing to startup items, resulting in \nremote control.","descriptionLong":"iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal \nvulnerability. When the software loads a malicious ‘ems' project \ntemplate file constructed by an attacker, it can write files to \narbitrary directories. This can lead to overwriting system files, \ncausing system paralysis, or writing to startup items, resulting in \nremote control.","published":"2024-10-24T17:41:56.069Z","updated":"2026-06-17T06:55:23.667Z","reserved":"2024-10-23T18:25:15.297Z","status":"Deferred","rejected":false,"assigner":"icscert","metric":{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"icscert"},"metrics":[{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"icscert"},{"version":"4.0","score":8.6,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"hq.dhs.gov"},{"version":"3.1","score":8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"icscert"},{"version":"3.1","score":8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"hq.dhs.gov"}],"rating":"high","products":["iniNet Solutions SpiderControl SCADA PC HMI Editor"],"affectedProducts":[{"vendor":"iniNet Solutions","product":"SpiderControl SCADA PC HMI Editor","defaultStatus":"unaffected","versions":[{"status":"affected","version":"8.10.00.00"}],"platforms":[]}],"packages":[],"cwes":["CWE-22"],"aliases":[],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-298-02","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.005,"epssPercentile":0.43636,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2024-10313","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-10313","ok":true,"note":"Deferred"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2024-10313","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2024-10313","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}