{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2023-5987","id":"CVE-2023-5987","title":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could…","description":"\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n","descriptionLong":"\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n","published":"2023-11-15T03:48:50.993Z","updated":"2026-06-17T06:49:48.387Z","reserved":"2023-11-07T10:58:51.030Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","rating":"medium","source":"schneider"},"metrics":[{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","rating":"medium","source":"schneider"},{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","rating":"medium","source":"se.com"},{"version":"3.1","score":6.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","rating":"medium","source":"NVD"}],"rating":"medium","products":["Schneider Electric EcoStruxure Power Monitoring Expert (PME)","Schneider Electric EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module","Schneider Electric EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module"],"affectedProducts":[{"vendor":"Schneider Electric","product":"EcoStruxure Power Monitoring Expert (PME)","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Version 2020 CU2 and prior"},{"status":"affected","version":"Version 2021 CU1 and prior"}],"platforms":[]},{"vendor":"Schneider Electric","product":"EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021"},{"status":"affected","version":"Advanced Reporting and Dashboards Module 2020 prior to CU3"}],"platforms":[]},{"vendor":"Schneider Electric","product":"EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module","defaultStatus":"unaffected","versions":[{"status":"affected","version":"EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2"}],"platforms":[]}],"packages":[],"cwes":["CWE-79"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf","tags":["x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00478,"epssPercentile":0.42076,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2023-5987","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-5987","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2023-5987","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2023-5987","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}