{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2023-4985","id":"CVE-2023-4985","title":"Supcon InPlant SCADA Project.xml improper authentication","description":"A vulnerability classified as critical has been found in Supcon InPlant SCADA up to 20230901. Affected is an unknown function of the file Project.xml. The manipulation leads to improper authentication. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-239796. NOTE: The vendor was contacted early about t","descriptionLong":"A vulnerability classified as critical has been found in Supcon InPlant SCADA up to 20230901. Affected is an unknown function of the file Project.xml. The manipulation leads to improper authentication. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-239796. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","published":"2023-09-15T14:00:10.223Z","updated":"2026-06-17T06:39:02.530Z","reserved":"2023-09-15T06:20:11.996Z","status":"Modified","rejected":false,"assigner":"VulDB","metric":{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","rating":"medium","source":"VulDB"},"metrics":[{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","rating":"medium","source":"VulDB"},{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","rating":"medium","source":"vuldb.com"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"},{"version":"3.0","score":5.9,"vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","rating":"medium","source":"VulDB"},{"version":"2.0","score":4.6,"vector":"AV:L/AC:L/Au:N/C:P/I:P/A:P","rating":"medium","source":"VulDB"},{"version":"2.0","score":4.6,"vector":"AV:L/AC:L/Au:N/C:P/I:P/A:P","rating":"medium","source":"vuldb.com"}],"rating":"medium","products":["Supcon InPlant SCADA"],"affectedProducts":[{"vendor":"Supcon","product":"InPlant SCADA","defaultStatus":null,"versions":[{"version":"20230901","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-287"],"aliases":[],"references":[{"url":"https://vuldb.com/?id.239796","tags":["vdb-entry","technical-description","x_transferred","Third Party Advisory"]},{"url":"https://vuldb.com/?ctiid.239796","tags":["signature","permissions-required","x_transferred","Permissions Required","Third Party Advisory"]},{"url":"https://drive.google.com/file/d/1V_O95QddCGdZzYGgx7tkMOYQ5i_alv69/view?usp=drive_link","tags":["exploit","x_transferred","Exploit"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":true,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00377,"epssPercentile":0.32268,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2023-4985","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-4985","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2023-4985","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2023-4985","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}