{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2023-45601","id":"CVE-2023-45601","title":"Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions…","description":"A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS fi","descriptionLong":"A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)","published":"2023-10-10T10:21:47.253Z","updated":"2026-06-17T06:28:54.157Z","reserved":"2023-10-09T09:36:15.785Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","rating":"high","source":"siemens"},"metrics":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","rating":"high","source":"siemens"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"siemens.com"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"}],"rating":"high","products":["Siemens Parasolid V35.0","Siemens Parasolid V35.1","Siemens Parasolid V36.0","Siemens Tecnomatix Plant Simulation V2201","Siemens Tecnomatix Plant Simulation V2302"],"affectedProducts":[{"vendor":"Siemens","product":"Parasolid V35.0","defaultStatus":"unknown","versions":[{"version":"All versions < V35.0.262","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"Parasolid V35.1","defaultStatus":"unknown","versions":[{"version":"All versions < V35.1.250","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"Parasolid V36.0","defaultStatus":"unknown","versions":[{"version":"All versions < V36.0.169","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2201","defaultStatus":"unknown","versions":[{"version":"All versions < V2201.0009","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","defaultStatus":"unknown","versions":[{"version":"All versions < V2302.0003","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-121","CWE-787"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf","tags":["x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00249,"epssPercentile":0.16421,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2023-45601","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-45601","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2023-45601","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2023-45601","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}