{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2023-4212","id":"CVE-2023-4212","title":"Trane Thermostats Injection","description":"\n​A command injection vulnerability exists in Trane XL824, XL850, XL1050, and Pivot thermostats allowing an attacker to execute arbitrary commands as root using a specially crafted filename. The vulnerability requires physical access to the device via a USB stick.\n\n","descriptionLong":"\n​A command injection vulnerability exists in Trane XL824, XL850, XL1050, and Pivot thermostats allowing an attacker to execute arbitrary commands as root using a specially crafted filename. The vulnerability requires physical access to the device via a USB stick.\n\n","published":"2023-08-22T17:34:12.059Z","updated":"2026-06-17T06:37:19.600Z","reserved":"2023-08-07T15:55:44.537Z","status":"Modified","rejected":false,"assigner":"icscert","metric":{"version":"3.1","score":6.8,"vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"medium","source":"icscert"},"metrics":[{"version":"3.1","score":6.8,"vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"medium","source":"icscert"},{"version":"3.1","score":6.8,"vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"medium","source":"hq.dhs.gov"},{"version":"3.1","score":6.8,"vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"medium","source":"NVD"}],"rating":"medium","products":["​Trane Technologies XL824 Thermostat","​Trane Technologies XL850 Thermostat","​Trane Technologies XL1050 Thermostat","Trane Technologies Pivot Thermostat"],"affectedProducts":[{"vendor":"​Trane Technologies","product":"XL824 Thermostat","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"5.9.8 ","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"​Trane Technologies","product":"XL850 Thermostat","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"5.9.8","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"​Trane Technologies","product":"XL1050 Thermostat","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"5.9.8 ","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"Trane Technologies","product":"Pivot Thermostat","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"1.8 ","status":"affected","version":"0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-74","CWE-77"],"aliases":[],"references":[{"url":"https://https://www.cisa.gov/news-events/ics-advisories/icsa-23-234-02","tags":["x_transferred","Broken Link"]},{"url":"https://hub.tranetechnologies.com/docs/DOC-216377","tags":["x_transferred","Permissions Required"]},{"url":"https://www.trane.com/commercial/north-america/us/en/contact-us/locate-sales-offices.html","tags":["x_transferred","Product"]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-234-02","tags":["Third Party Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.01332,"epssPercentile":0.71732,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2023-4212","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-4212","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2023-4212","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2023-4212","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}