{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2023-31157","id":"CVE-2023-31157","title":"Improper Neutralization of Input During Web Page Generation","description":"\nAn Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n","descriptionLong":"\nAn Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n","published":"2023-05-10T19:22:58.877Z","updated":"2026-06-17T05:56:25.030Z","reserved":"2023-04-24T23:19:04.959Z","status":"Modified","rejected":false,"assigner":"SEL","metric":{"version":"3.1","score":4.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L","rating":"medium","source":"SEL"},"metrics":[{"version":"3.1","score":4.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L","rating":"medium","source":"SEL"},{"version":"3.1","score":4.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L","rating":"medium","source":"selinc.com"},{"version":"3.1","score":5.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","rating":"medium","source":"NVD"}],"rating":"medium","products":["Schweitzer Engineering Laboratories SEL-3505","Schweitzer Engineering Laboratories SEL-3505-3","Schweitzer Engineering Laboratories SEL-3530","Schweitzer Engineering Laboratories SEL-3530-4","Schweitzer Engineering Laboratories SEL-3532","Schweitzer Engineering Laboratories SEL-3555","Schweitzer Engineering Laboratories SEL-3560S","Schweitzer Engineering Laboratories SEL-3560E","Schweitzer Engineering Laboratories SEL-2241 RTAC module","Schweitzer Engineering Laboratories SEL-3350"],"affectedProducts":[{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-3505","defaultStatus":"unaffected","versions":[{"lessThan":"R150-V2","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R149-V4","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R148-V7","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R147-V6","status":"affected","version":"R132-V0","versionType":"custom"}],"platforms":["Linux"]},{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-3505-3","defaultStatus":"unaffected","versions":[{"lessThan":"R150-V2","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R149-V4","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R148-V7","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R147-V6","status":"affected","version":"R132-V0","versionType":"custom"}],"platforms":["Linux"]},{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-3530","defaultStatus":"unaffected","versions":[{"lessThan":"R150-V2","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R149-V4","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R148-V7","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R147-V6","status":"affected","version":"R132-V0","versionType":"custom"}],"platforms":["Linux"]},{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-3530-4","defaultStatus":"unaffected","versions":[{"lessThan":"R150-V2","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R149-V4","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R148-V7","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R147-V6","status":"affected","version":"R132-V0","versionType":"custom"}],"platforms":["Linux"]},{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-3532","defaultStatus":"unaffected","versions":[{"lessThan":"R150-V2","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R149-V4","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R148-V7","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R147-V6","status":"affected","version":"R132-V0","versionType":"custom"}],"platforms":["Linux"]},{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-3555","defaultStatus":"unaffected","versions":[{"lessThan":"R150-V2","status":"affected","version":"R134-V0","versionType":"custom"},{"lessThan":"R149-V4","status":"affected","version":"R134-V0","versionType":"custom"},{"lessThan":"R148-V7","status":"affected","version":"R134-V0","versionType":"custom"},{"lessThan":"R147-V6","status":"affected","version":"R134-V0","versionType":"custom"}],"platforms":["Linux"]},{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-3560S","defaultStatus":"unaffected","versions":[{"lessThan":"R150-V2","status":"affected","version":"R144-V2","versionType":"custom"},{"lessThan":"R149-V4","status":"affected","version":"R144-V2","versionType":"custom"},{"lessThan":"R148-V7","status":"affected","version":"R144-V2","versionType":"custom"},{"lessThan":"R147-V6","status":"affected","version":"R144-V2","versionType":"custom"}],"platforms":["Linux"]},{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-3560E","defaultStatus":"unaffected","versions":[{"lessThan":"R150-V2","status":"affected","version":"R144-V2","versionType":"custom"},{"lessThan":"R149-V4","status":"affected","version":"R144-V2","versionType":"custom"},{"lessThan":"R148-V7","status":"affected","version":"R144-V2","versionType":"custom"},{"lessThan":"R147-V6","status":"affected","version":"R144-V2","versionType":"custom"}],"platforms":["Linux"]},{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-2241 RTAC module","defaultStatus":"unaffected","versions":[{"lessThan":"R150-V2","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R149-V4","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R148-V7","status":"affected","version":"R132-V0","versionType":"custom"},{"lessThan":"R147-V6","status":"affected","version":"R132-V0","versionType":"custom"}],"platforms":["Linux"]},{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-3350","defaultStatus":"unaffected","versions":[{"lessThan":"R150-V2","status":"affected","version":"R148-V0","versionType":"custom"},{"lessThan":"R149-V4","status":"affected","version":"R148-V0","versionType":"custom"},{"lessThan":"R148-V7","status":"affected","version":"R148-V0","versionType":"custom"}],"platforms":["Linux"]}],"packages":[],"cwes":["CWE-79"],"aliases":[],"references":[{"url":"https://selinc.com/support/security-notifications/external-reports/","tags":["x_transferred","Vendor Advisory"]},{"url":"https://www.nozominetworks.com/blog/","tags":["x_transferred","Third Party Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00439,"epssPercentile":0.38926,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2023-31157","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-31157","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2023-31157","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2023-31157","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}