{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2023-29410","id":"CVE-2023-29410","title":"A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same…","description":"\nA CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated\nattacker to gain the same privilege as the application on the server when a malicious payload is\nprovided over HTTP for the server to execute. \n\n \n\n\n\n","descriptionLong":"\nA CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated\nattacker to gain the same privilege as the application on the server when a malicious payload is\nprovided over HTTP for the server to execute. \n\n \n\n\n\n","published":"2023-04-18T21:13:55.322Z","updated":"2026-06-17T05:49:59.433Z","reserved":"2023-04-05T20:35:41.367Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":7.2,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"schneider"},"metrics":[{"version":"3.1","score":7.2,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"schneider"},{"version":"3.1","score":7.2,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"se.com"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"}],"rating":"high","products":["Schneider Electric InsightHome","Schneider Electric InsightFacility","Schneider Electric Conext Gateway"],"affectedProducts":[{"vendor":"Schneider Electric","product":"InsightHome","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"v1.16 Build 004","versionType":"custom"}],"platforms":[]},{"vendor":"Schneider Electric","product":"InsightFacility","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"v1.16 Build 004","versionType":"custom"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Conext Gateway","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"v1.16 Build 004","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-20"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-02.pdf","tags":["x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00661,"epssPercentile":0.52434,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2023-29410","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-29410","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2023-29410","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2023-29410","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}